Service Tests
Perform tests to help you troubleshoot systems including torque, WATTS, RPM, battery and generator voltage and amps, and
display elements.
Press the white button to move from one test to the next.
Setting Description
DISP TEST Tests the display to make sure all elements are working. Select YES to test the display. No is the default.
BAT VOLT Battery voltage: While you pedal or if you have an external charger installed, the voltage will appear high
because the battery is charging. When you stop pedaling, you will see the actual (true) voltage.
BAT AMP Battery amp: Battery current being discharged.
GEN VOLT Generator voltage: Speed of pedaling affects the voltage number.
GEN AMP Generator amp: Current being supplied by generator.
USB LOGS Data from this setting is stored in Log directory.