On
Off
Motor Controller Light - has only three states:
Off
No power
to the MC
Solid
Green
All OK
electrically
Solid
Yellow
Had error,
recovered
Drive Motor and Input Voltage/Current Measurements-
It is no longer necessary to connect a voltmeter or ammeter to the treadmill to see the wall input
voltages and the currents and motor drive voltages and the currents.
By accessing the Belt Speed test from the diagnostics menus it is possible to see the following:
Voltage In (the voltage from the wall outlet)
Buss Voltage (the voltage to the motor from the MC)
Buss Current
Current In
On the P80 this information will be displayed as part of a list of information when the test is
running. To display this information on the P10/P30 you must use the UP and DOWN arrows to
select this. In both cases it will be necessary to start the test by pressing the Speed Up
button/toggle to see the results of the measurements.