Connecting 120VAC Loads to the Generator
Calculate Power Draw:
Power draw can be calculated by multiplying volts and amps. The resulting number is wattage.
Never exceed the running wattage for the Generator or any outlet amperage rating.
Refer to appliance/tool owner’s manuals to determine the wattage of electrical load devices.
Long power cords and extension cords draw additional power. Keep cord length at a minimum.
Wattage Estimates
Wattages listed below are estimates for that type of equipment only.
Check nameplate wattages on all loads before connecting to Generator.
This Unit Can Power Any
One of the Following Items:
Running
Watts
Start-up
Watts
1/4 HP Air Compressor 600 900
1/6 HP Motor 500 800
3/8" Drill 400 600
Mini Refrigerator 400 700
Table/Box Fan 200
15 Amp Battery Charger 380
String Trimmer 350
Hedge Trimmer 500
Radio 50
Ten 75 Watt Light Bulbs 750
Figure A: Plug Load In
Plug the power cord of the 120 volt appliance/tool
into the 120VAC Outlet on the Generator. Plug in
appliances from largest to smallest load.
Note: Do not allow the Generator to completely run
out of fuel with devices attached. A Generator’s
output may sharply spike as it runs out of fuel,
causing damage to attached devices.
Overload Light
Note: The OVERLOAD light may turn on for a few seconds as a large device starts up.
This is normal for loads approaching the capacity of this Generator.
1. The total combined load through the
outlet on the Generator must not exceed
the running power of the unit.
2. If the OVERLOAD light turns on and the Generator
stops producing power, it has been overloaded.
3. Disconnect all electrical devices, and
compare device requirements to Generator rating.
Move anything that may be limiting
Generator ventilation away.
4. Press and hold Overload Reset button
above the Dual 120VAC Receptacle
until OVERLOAD light turns off.
5. Reconnect devices while being careful
to not overload Generator.
OFF
RUN
START
LOW OIL
OVERLOAD
OUTpUT
pARALLEL OUTLETS
RESET
AC 120V
RESET
DC 12V
ESC
THROTTLE
LOW OIL
OVERLOAD
OUTPUT
OFF
RUN
START
LOW OIL
OVERLOAD
OUTpUT
pARALLEL OUTLETS
RESET
AC 120V
RESET
DC 12V
ESC
THROTTLE
Overload
Reset
Button
Economy (ESC) Switch
1. Turn the Economy (ESC) Switch ON to limit noise
and fuel consumption for lighter generator loads.
2. Turn the Economy (ESC) Switch OFF
to operate engine at full speed:
a. when starting,
b. when a heavy load is applied, or
c. when using the 12VDC output.