Pregis AIRSPEED 5000 - Main Screen “Ready to Run” Message Replaced W. “Change Belts”

Pregis AIRSPEED 5000
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Solution: Replace the sealing wire.
NOTE: Allow the seals to cool for approxi-
mately one minute before testing.
Cause: Sealing wire not hot enough.
Solution: Adjust the sealing temperature.
Cause: Air pressure blowing out seals.
Solution: Decrease the inflation air pressure
to prevent over inflating.
Check that the upper guard/clamp is
seated properly on lower block, iso-
lating the seal from inflation.
Check that the lower platen is
pivoting properly.
Check that the lower platen stiff,
outer plastic (Durit
TM
) sealing sur-
face is securely mounted to the
lower layer of soft silicone.
Ensure both nips are fully closed. It
is critical that the outfeed nip is pro-
viding the proper nip pressure on
the seal.
Cause: Film not held tight together between
sealing belts.
Solution: Check to ensure the upper
guard/clamp is lowered/closed.
Cause: Sealing belts are worn.
Solution: Replace sealing belts as necessary.
6. Problem: Main screen “Ready To Run” mes-
sage replaced with “Change Belts” message.
Cause: Belt Odometer screen has reached
the preset belt change interval
value.
Solution: Replace the sealing belt(s) and have
Management reset the Actual value
on the Belt Odometer screen to
zero (0) meters.
NOTE: Refer to the Sealing Belt Replacement
instruction for more information.