EasyManua.ls Logo

Prestige Solo - Hot Water and Gas Categories

Prestige Solo
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN 8
ENGLISHFRANCAISNEDERLANDSESpAñoLITALIANoDEuTSCH
664Y2300.C
TECHNICAL CHARACTERISTICS
PROPANE MODEL
Solo P Excellence P
 24 32 24 32
Max. Input 80/60°C
kW
24 30,5 24 30,5
Min. Input 80/60°C
kW
5,9 5,9 5,9 5,9
Max. output 80/60°C
kW
23,4 29,6 23,4 29,6
Min. output 80/60°C
kW
5,8 5,8 5,8 5,8
Efficiency 30% load [EN677]
%
109 109 109 109

Flue gas pipe - Max. pressure drop
Pa
130 130 130 130
Concentric flue gas channel maximum length Ø 80 / 125 mm
m
20 20 20 20

Propane gas pressure
mbar
30 / 37 / 50
G31 gas flow rate
m
3
/h
0,98 1,3 0,98 1,3
CO
2
max. Input G31 (with front panel closed)
% CO
2
11 11 11 11
CO
2
max. Input G31 (with front panel open)
% CO
2
10,7 10,7 10,7 10,7
CO
2
max. Input G31 (with front panel closed)
% CO
2
10,9 10,9 10,9 10,9

Max. operating temperature
°C
90 90 90 90
Boiler water capacity
L
8 8 16 16
Domestic hot water circuit capacity
L
54 54
Maximum operating pressure central heating
bar
3 3 3 3
Heat exchanger pressure drop [T = 20°C]
mbar
131 210 131 210
Capacity of the expansion vessel
(depend of countries)
L
12 12

Class
IP
30 30 30 30
Supply voltage
V/Hz
230 / 50 230 / 50 230 / 50 230 / 50
Maximum absorbed electrical power
A
0,8 0,8 1,2 1,2
 kg 48 48 92 92
DOMESTIC HOT WATER FEATURES

Excellence 24 Excellence 32
Peak flow at 40°C [T = 30°C]
L/10’
175 224
Peak flow at 40°C [T = 30°C]
L/60’
733 835
Constant flow at 40°C [T = 30°C]
L/h
653 745
Peak flow atv 60°C [T = 50°C]
L/10’
102 103
Peak flow at 60°C [T = 50°C]
L/60’
352 353
Constant flow at 60°C [T = 50°C]
L/h
316 320
Pre-heat time
minutes
27 25

Related product manuals