24 – CS 300 Gate Controls / Rev.D 5.6
SYSTEM
Pro-Line
C. Impulse signals
MOD Description Remarks
MOD 4 Impulse when there is an OPEN command The relay closes the contact for 1 second when the door receives an OPEN command.
This impulse can be used to control lights, for instance.
MOD 27 Impulse when OPEN end position is reached The relay closes the contact for 2 seconds when the door reaches the OPEN end
position.
This impulse can be used, for instance, to open a following photocell.
D. Brake functions
MOD Description Remarks
MOD 14 Brake (normally energised mode) Theswitchingcontactofthebrakerectierisactivatedviatherelaytoachievea
faster brake function. As soon as the door starts to move, the contact closes and the
brake is released (normally energised mode).
MOD 15 Brake (normally de-energised mode) Theswitchingcontactofthebrakerectierisactivatedviatherelaytoachievea
faster brake function. As soon as the door starts to move, the contact opens and the
brake is released (normally de-energised mode).
MOD 16 Brake (normally energised mode) switched on in
OPEN end position
Theswitchingcontactofthebrakerectierisactivatedviatherelaytoachievea
faster brake function. As soon as the door starts to move, the contact closes and
the brake is released (normally energised mode). IN ORDER TO STOP THE DOOR
MORE SMOOTHLY AT THE UPPER END POSITION, THE SWITCHING CONTACT IS NOT
SWITCHED AT THE OPEN END POSITION (OPEN TIME).
E. Error messages
MOD Description Remarks
MOD 5 Error message The relay opens the contact when a STOP command is given or an error occurs. All
errors described in Section 10 result in actuation of the relay.
MOD 17 Closing edge safety device actuated The relay opens the contact when the closing edge safety device is actuated. An error
in the closing edge safety device or an unsuccessful test is shown via MOD5.