3 1/2 2A Mini Digital Clamp Meter user manual
5
4. Measuring methodDual slope integration A/D
converter
5. Sampling speed2-3 time/sec
6. Unit displayFunction and unit symbols displayed
7. PolarityAutomatic negative polarity display
8. Overload indicationSymbol “1”appears on the LCD
9. Low battery indicationSymbol appears on the LCD
10. Auto power off time15min
11. Operation temperature0~40,75%RH
12. Storage temperature-20~60, 75%RH
13. Operation power1.5V x 3AAA Batteries
14. Dimension203mm(L)x68mm(W)x33mm(D)
15. Weight187gwithout battery
BUTTON FUNCTION AND AUTO POWER OFF
1. HOLD: For measuring data hold, press the HOLD button,
the peak value of current data will be keeping displaying
on LCD; press it again to cancel this function
2. MAX: Maximum data hold button, when press this button,
the A/D converter will keep measuring, and the display
updating the data and hold the maximum data
3. SELECTFunction selection button, press for switching
ohm / diode /continuity/ temperature function when tested
objects change
4. Auto-power off : If there is no any operation within any
fifteen minutes after power is on, the meter will auto power
off. Turn the rotary selector or press any function button to
resume operation of the meter under the auto power off