IMPORTANT: Read and understand this manual before
assembling, starting or servicing heater. Improper use
of heater can cause serious injury. Keep this manual for
future reference.
Never use heater in living or sleeping areas.
Heater is suitable for outdoor use and for use on com-
bustible oors.
PORTABLE FORCED AIR HEATERS
KEROSENE/DIESEL HEATER WITH BUILT-IN THERMOSTAT
OWNER’S MANUAL
PCK110VT - ADJUSTABLE 80-110,000 BTU/HR
PCK160VT - ADJUSTABLE 110-160,000 BTU/HR
PCK175VT - ADJUSTABLE 125-175,000 BTU/HR
PCK220VT - ADJUSTABLE 160-220,000 BTU/HR
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 7:30 am - 4:15 pm CST,
Monday through Friday or email customerservice@usaprocom.com

Questions and Answers

  • G
    gthomasAug 14, 2025
    What to do if my Procom PCK110VT Heater motor starts but doesn't ignite?
    • R
      Robert SmithSep 12, 2025
      If the Procom Heater's motor starts but the heater doesn't ignite, there could be several reasons. Check for leaks in the air lines or fittings and correct any leaks. Also, inspect the pump cover for leaks and tighten the pump cover screws to 10-20 in-lbs. If the pump output filter is clogged, replace it. You may also need to see Pump Pressure Adjustment page 14. Adjust pump pressure to specification. You may also need to service pump, see page 17.
  • G
    Gregory McculloughAug 17, 2025
    What to do if Procom Heater ignites then shuts off quickly?
    • R
      Robin BrayAug 18, 2025
      If your Procom Heater ignites but the control assembly shuts it off before it runs out of fuel, several factors could be at play. Ensure there's enough fuel in the tank to maintain combustion. If there is water in the fuel tank, drain and flush it with kerosene. Also, a dirty photocell lens can cause this issue, so clean the photocell lens. You may also need to replace photocell.
  • R
    Rebecca ObrienAug 21, 2025
    Why my Procom PCK110VT won't start when voltage is too high?
    • D
      Dawn SloanAug 21, 2025
      If the motor of your Procom Heater doesn't start after plugging it in and turning it on, it might be due to the supply voltage being above 135 volts. Confirm that the supply voltage is below 135 volts.
  • T
    Tammy ClineAug 25, 2025
    Why Procom PCK110VT Heater motor does not start in hot environment?
    • Q
      qmartinezAug 25, 2025
      If the motor of your Procom Heater doesn't start after plugging it in and turning it on, it might be because the room or ambient temperature exceeds 100°F. Operate the heater in a cooler environment.
  • D
    Daniel HornAug 27, 2025
    What to do if Procom PCK110VT won't start due to low voltage?
    • M
      Marcus GarnerAug 27, 2025
      If the motor of your Procom Heater doesn't start after plugging it in and turning it on, it might be due to the supply voltage being below 95 volts. Confirm that the supply voltage is above 95 volts. See extension cord requirements on page 7.
  • G
    George GreenAug 31, 2025
    What to do if Procom PCK110VT Heater motor is locked?
    • L
      Lawrence MitchellAug 31, 2025
      If the motor of your Procom Heater doesn't start after plugging it in and turning it on, it might be due to a bad electrical connection between the motor and power cord, a fan obstruction, a pump obstruction, or a defective motor. Unplug the heater and check all electrical connections (see Wiring Diagram, page 18). Clear any fan obstructions. Service the pump (see page 17). If necessary, replace the motor.
  • D
    davissamanthaSep 3, 2025
    Why Procom PCK110VT motor does not start after plugging in?
    • R
      Robert WrightSep 3, 2025
      If the motor of your Procom Heater doesn't start after plugging it in and turning it on, it might be due to several reasons. First, the control might remember codes from a prior operation; try pressing the MODE/RESET button to clear the code and restart the heater. Also, your thermostat setting could be too low; adjust it to a higher setting or switch to MANUAL MODE by pressing the MODE/RESET button.
  • C
    corey68Sep 6, 2025
    How to check power connection of Procom Heater?
    • C
      Christopher CarneySep 6, 2025
      If the motor of your Procom Heater doesn't start after plugging it in and turning it on, it might be because there's no power to the heater. Check the power cord connections and all electrical connections, referring to the Wiring Diagram on page 18.
  • A
    Anna BarrettSep 9, 2025
    What causes Procom PCK110VT Heater to shut off if button stuck?
    • R
      Robert SalazarSep 9, 2025
      If your Procom Heater ignites but the control assembly shuts it off before it runs out of fuel, it could be because one or more of the control buttons is stuck. Unplug the heater and depress and release each control button several times to check operation. Every button should click every time it is depressed. If the issue persists, the control assembly may be defective and needs replacement.

Summary

Safety Information

Setup Procedures

Unpacking

Instructions for removing items from the shipping carton and checking for damage.

Assembly

Instructions for assembling the heater components, such as wire guards and handles.

Product Details

Product Identification and Label Locations

Identifies the location and purpose of various labels on the heater unit.

Specifications

Details output rating, fuel capacity, consumption, electric requirements, and motor specs.

Fuels

Lists approved fuels and warnings against using incorrect fuel types.

Ventilation

Specifies required fresh air openings for safe operation and carbon monoxide prevention.

Operation and Maintenance

Operation Guide

Step-by-step instructions for safely starting, stopping, and operating the heater.

Operation with Portable Generator

Guidelines for safely operating the heater using a portable generator.

Storing, Transporting or Shipping

Procedures for safely storing, moving, or shipping the heater.

Preventative Maintenance Schedule

Outlines recommended maintenance tasks and their frequency.

Troubleshooting and Service

Troubleshooting

Lists common fault conditions, possible causes, and remedies for heater issues.

Service Procedures

Detailed instructions for performing maintenance and repairs on heater components.

Wiring Diagram

Visual representation of the heater's electrical connections and components.

Support and Parts

Technical Service

Contact information and resources for obtaining technical assistance.

Accessories

Information on available accessories for the heater, like gauge kits.

Parts List

Comprehensive list of replaceable parts with item numbers and descriptions.

Warranty Information

Details the terms, conditions, and limitations of the product warranty.

Procom PCK110VT Specifications

General IconGeneral
BrandProcom
ModelPCK110VT
CategoryHeater
LanguageEnglish

Related product manuals