13
TO TURN OFF GAS
TO APPLIANCE
Push in gas Control Knob slightly and
turn clockwise to the OFF position.
Do not force.
When electric power is available and
electric operation is desired, turn clock -
wise to OFF position for one minute.
Then press down knob and rotate clock -
wise to ELECTRIC position.
Do not operate between locked posi -
tions.
MANUAL LIGHTING
PROCEDURE
(match light)
1. Open front door.
2. Follow steps 1 through 5 under
MANUAL OPERATING Lighting
Instructions .
3. With Control Knob in PILOT/IGN
position, strike match, and hold near
pilot. Press in Control Knob, pilot
should light.
4. Keep Control Knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release Control Knob. Fol -
low step 9 under MANUAL OPERAT -
ING Lighting Instructions.
Figure 16 - Manual Control
5. Wait five (5) minutes to clear out
any gas. Then smell for gas, includ -
ing near the floor. If you smell gas,
STOP! Follow “B” in the safety infor -
mation on page 11. If you do not smell
gas, go to the next step.
6. Push in gas control slightly and turn
counterclockwise to PILOT/IGN
and depress for five (5) seconds.
NOTE : The first time that the heater
is operated after connecting the gas
supply, the control knob should be
depressed for about thirty (30) sec -
onds. This will allow air to bleed from
the gas system.
7. With Control Knob pressed in, push
and release the ignitor button. This
will light the pilot. If needed, keep
pressing ignitor button until pilot
lights.
8. Keep Control Knob depressed for
ten (10) seconds after lighting pilot.
If pilot goes out, repeat steps 6, 7
and 8.
9. Turn counterclockwise to “ON”
position. Do not operate between
locked positions.
MANUAL OPERATING
INSTRUCTIONS
Continued