3302F Mainframe Operation Manual 43
MODEL
STAGE COMMAND
331XF
333XF
334XF/G
33401F/G
REMARK
[STATe]POLAR{SP}{POS│NEG}{NL}
V V V V
[STATe]START{│NL}
V V V V
[STATe]STOP{│NL}
V V V V
[STATe] TESTING {?}{NL}
V V V V
0TEST END
1TESTING
TABLE 4-5B STAGE COMMAND SUMMARY
SYSTEM COMMAND: available for all module
COMMAND NOTE RETURN
[SYStem] CHANnel {SP} [A B] {NL}
A B “ for 333XFand 33401F/G
[SYStem] CHANnel {?}{NL}
A B “ for 333XFand 33401F/G
[AB]
[SYStem] RECall {SP} {m [,n] }{NL}
m=1~10 n=1~15
[SYStem] STORe {SP} {m [,n] }{NL}
m=1~10 n=1~15
[SYStem] REMOTE {NL}
RS232/USB/LAN command
[SYStem] LOCAL{ NL}
RS232/USB/LAN command
[SYStem] NAME {?} { NL}
“XXXXX”
[SYStem]*RST {NL}
TABLE 4-6B SYSTEM COMMAND SUMMARY
MEASURE COMMAND: AVAILABLE FOR ALL MODULE
COMMAND 331XF
333XF
334XF/G
33401F/G
RETURN
MEASureCURRent{?}{NL}
V V V V ###.####
MEASureVOLTage{?}{NL}
V V V V ###.####
MEASurePOW{?}{NL}
V V V V ###.####
MEASVC{?}{NL}
V V V V ###.####,###.####
TABLE 4-7B MEASURE COMMAND SUMMARY