26 PRODIGIT
4.4. Computer Commands: Simple Type Format
The setting and query commands for the 3310F / 3330F / 3340F/G /33401F/G series of load
modules when operated within the 3302F mainframe are listed below in table 4-1 and 4-2.
MODEL
SETTING PRESET NUMERIC
COMMAND
331XF
333XF
334XF/G
33401F/G
REMARK
A/us(3310F,11F,12F),
mA/us(3314F,15F,333XF
RISE{SP} {NR2} {;NL}
V V V
334XF/G)
A/us(3310F,11F,12F),
mA/us(3314F,15F,333XF FALL{SP}{;NL}
V V V
334XF/G)
PERD:{HIGH LOW} {SP} {NR2}
{;NL}
V V V
LDONV{SP} {NR2} {;NL}
V V V V
LDOFFV{SP} {NR2} {;NL}
V V V V
CC CURR:{HIGH LOW} {SP}
{NR2}{;NL}
V V V
CC CURR{SP}{NR2}{;NL}
V
CP:{HIGH LOW} {SP} {NR2}{;
NL}
V V V
CR RES:{HIGH LOW} {SP}
{NR2}{;NL}
V V V
CR RES{SP}{NR2}{;NL}
V
CV VOLT:{HIGH LOW} {SP}
{NR2}{;NL}
V V V
CV VOLT{SP}{NR2}{;NL}
V
TCONFIG {SP} {NORMAL|OCP |
OPP | SHORT }{;|NL}
V V V V 33401F/G No OPP
OCP:START {SP} {NR2}{;|NL} V V V V
OCP:STEP {SP} {NR2}{;|NL} V V V V
OCP:STOP {SP} {NR2}{;|NL} V V V V
VTH {SP} {NR2}{;|NL} V V V V
OPP:START {SP} {NR2}{;|NL} V V V
OPP:STEP {SP} {NR2}{;|NL} V V V
OPP:STOP {SP} {NR2}{;|NL} V V V
STIME {SP} {NR2}{;|NL} V V V V