18
FAULTS & ERRORS
There are six error codes that may be displayed. These will be displayed in the
following way:
LCD Power On LED Fault Remedy
Err Slow Flashing Short circuit or reverse
connection of the clips
Check clips are not
touching each other
OR
Check the clips are
correctly connected
to the battery
F01 Fast Flashing Bulk charging has
timed out and stopped
after 22 hours
Battery may be faulty
– Slow Flashing The charger has
entered recondition
mode 3 times and
has timed out
Battery may be faulty
and may need replacing
OR
There is a load on the
battery causing the
battery to fail Analysis
OTP Fast Flashing The charger has
overheated and has
switched off
Ensure adequate
ventilation around
the charger
OLC Fast Flashing Sensor wires are not
connected to the
positive/negative
connections
If DC leads have been
cut for hardwiring, check
sensor wires are included
in both positive & negative
connections (Refer
to page 13, point 1)
OCP Fast Flashing The charger has
encountered an error
Contact Brown & Watson
International
SPECIFICATIONS
P/No. IC25, IC25W, IC25RV IC35 IC50 IC8-24
Type 7/5 stage 7/5 stage 7/5 stage 7/5 stage
Input (nominal) 230-240VAC, 50Hz 230-240VAC, 50Hz 230-240VAC, 50Hz 230-240VAC, 50Hz
Input Power 450W 570W 820W 270W
Output Voltage 12V 12V 12V 24V
Output Current 2, 6, 12, 25A 2, 8, 16, 35A 2, 6, 12, 25, 50A 2, 4, 6, 8A
Minimum Start Voltage 1.0V 1.0V 1.0V 2.0V
Back Drain 3mA 3mA 3mA 3mA