Type | Digital |
---|---|
Continuity Buzzer | Yes |
Diode Test | Yes |
Transistor Test | Yes |
Square Wave Output | Yes |
Data Hold | Yes |
Fuse Protection | Yes |
Display | 3 1/2 digits LCD |
DC Voltage Range | 200mV/2V/20V/200V |
AC Voltage Range | 200V |
DC Current Range | 200μA/2mA/20mA/200mA/10A |
Resistance Range | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ |
Battery | 9V |
Read manual carefully, avoid over-ranging, check leads, and ensure proper operation.
Details on LCD display, max display, measurement method, sampling rate, and overrange indication.
Specifications for operation environment, power source, size, and weight.
Accuracy, resolution, input resistance, and overload protection for DCV measurements.
Accuracy, resolution, input resistance, frequency response, and overload protection for ACV.
Accuracy, resolution, max input volt drop, max input current, and overload protection for DCA.
Accuracy, resolution, max measuring volt drop, max input current, and overload protection for ACA.
Accuracy, resolution, open voltage, and overload protection for Resistance measurements.
Accuracy, resolution, and overload protection for Capacitance measurements.
Accuracy and resolution for Temperature measurement using K-type thermocouple.
Conditions and display values for Diode and Continuity tests, including overload protection.
Range and test conditions for Triode hFE parameter measurement.
Identification and description of the multimeter's front panel controls and ports.
Step-by-step instructions for measuring DC Voltage, including range selection and connection.
Step-by-step instructions for measuring AC Voltage, including range selection and connection.
Step-by-step instructions for measuring DC Current, including jack selection and connection.
Step-by-step instructions for measuring AC Current, including jack selection and connection.
Step-by-step instructions for measuring Resistance, including connection and notes.
Step-by-step instructions for measuring Capacitance, including polarity and discharge notes.
Instructions for performing Diode and Continuity tests, including connection and expected readings.
Instructions for measuring temperature using the K-type thermocouple.
Instructions for performing Triode hFE tests, including transistor type and connection.
Explanation of the auto power off feature and how to control the LCD backlight.
Precautions regarding water, dust, shock, and environmental conditions.
Guidelines for cleaning the meter and storing it when not in use.
Instructions for replacing the 9V battery when the low battery symbol appears.
A table listing common problems like no display, low battery symbol, and large errors with their solutions.