21
CAN address
1=1
0~255
14
22
CAN baud rate
0=250
1=500
2=1000
other=500
2
23
RS232 baud rate
0=4800
1=9600
2=19200
3=38400
4=115200
1
24
RS232 mode
0=Proton protocol
1=Modbus protocol
2=ZM400 Printer
1
25
RS422/RS485 mode
0=Proton protocol
1=Modbus protocol
2=SSI speed protocol
3=SSI length protocol
1
26
RS422/RS485 baud rate
0=4800
1=9600
2=19200
3=38400
4=115200
5=250K
6=500K
7=1M
1
27
Modbus address
1=1
0~255
1
28
EtherNet protocol
0=Modbus protocol
1=EIP protocol
0
29
DHCP
0=Disabled
1=Enabled
0
30
IP address
x.x.x.x
C0A8016E
(192.168.1.110)
31
32
Subnet mask
x.x.x.x
FFFF0000
(255.255.0.0)
33
34
Gateway
x.x.x.x
C0A80001
(192.168.1.1)
35
36
CAN terminator
1=1
0=Off
1=On
0
37
38
Speed compensation
coefficient
1=0.0001
10000
39
Acceleration limit
1=1m{ft}{yd}/min/s
1~9999
9999
40
Reset parameters to
factory defaults
63000=factory default
other=invalid
41
UDP data output interval
time
1=1ms
1~5000
0=Disable UDP output
0
42
Analogue O/P gain
1=0.0001
9999
43
Analogue O/P zero
1=0.0001
0
44
Speed simulation
0=Normal
1=Simulation
0
45
Simulation speed
1=0.1m{ft}{yds}/min
0~6553.5
100
46
DeviceNet address
0~63
7
47
DeviceNet baud rate
0=125K
1=250K
2=500K
48
UDP destination IP
address (last octet only)
Note: the UDP destination port
number is fixed at 1111
2
49
Endianess
1=Little endian
0=Big endian
0