SPECIAL NOTE: The system will automatically switch to the following interface,
if there is no any operation for 2~3 seconds. Press OK/RETURN Button will save the
curve and back to the main menu.
STEP 4 When the temperature values at all time points are set, the new curve will be
automatically saved and returned to the main menu.
SPECIAL MOTE: The settable time range of the self-set curve is: 0~480 seconds,
and the settable temperature range: 40~280°C. The software has a temperature
protection function. If the temperature value set at the current time point is too high
compared with the temperature value set at the previous time point, the setting
cannot be successful.