EasyManuals Logo
Home>Pulsar>Portable Generator>PGDA70BiSCO

Pulsar PGDA70BiSCO User Manual

Pulsar PGDA70BiSCO
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
13
Operation
WARNING
6. Choose the starting method
Recoil Start: Firmly grasp and pull the recoil handle slowly until
you feel resistance, let it retract then pull swiftly.
Push-Button Start: Press the start button down for 1-3 seconds,
then release, to start the generator.
Remote Start: Push and hold the ON button on the remote start
key fob for one second.
7. Plug in devices
Gasoline To LPG
IMPORTANT: Load capacity is reduced when running on LPG. Make
sure the generator can supply enough (running) and surge (starting)
watts for the items you are powering before switching to LPG.
1. Turn the LPG tank valve to the fully open position.
2. Turn the fuel selector switch to propane operation.
LPG To Gasoline
1. Turn the fuel selector switch to gasoline operation.
2. Turn the LPG tank valve to the fully closed position.
NOTE: When switching to LPG operation the engine may run rough
for a few seconds while it purges gasoline from the carburetor.
If the engine stops when switching fuel sources, disconnect all loads
then restart the unit on the fuel source of choice.
Parallel Operation
The parallel connection ports allow you to connect two generators
to increase the total available electrical power. Follow the
instructions included with your parallel connection kit for proper
installation and operation.
Overload Indicator
Note: The OVERLOAD light may turn on for a few seconds as a
large device starts. This is normal for loads approaching the
capacity of this generator.
1.The total combined load through the outlets on the generator
must not exceed the running power of the unit.
Activation Light
START Button
STOP Button
START
STOP
When using the generator with propane, make sure there is no
possible ignition source close to the generator.
Fire and explosion hazard. Always turn the propane tank valve
to the fully closed position if not running the generator on
propane.
DANGER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pulsar PGDA70BiSCO and is the answer not in the manual?

Pulsar PGDA70BiSCO Specifications

General IconGeneral
BrandPulsar
ModelPGDA70BiSCO
CategoryPortable Generator
LanguageEnglish

Related product manuals