EasyManuals Logo
Home>Pulsar>Portable Generator>PGDA70BiSCO

Pulsar PGDA70BiSCO User Manual

Pulsar PGDA70BiSCO
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
14
Operation
2. If the OVERLOAD light turns on and the generator stops
producing power, it has been overloaded.
3. Turn off and disconnect all electrical devices and stop the
engine. Compare device requirements to generator rating and
reduce the total wattage of connected devices if necessary.
Move anything that may be limiting generator ventilation away.
4. Check if any circuit breakers have tripped and make sure that
ALL circuit breakers are reset before starting the generator again.
5. Restart the engine and reconnect devices while being careful
to not overload the generator.
Low Oil Indicator
1. If the engine oil level is too low, the LOW OIL light turns on
and the engine will automatically shut off.
2. The engine cannot be restarted until the proper amount of oil
has been added. Add the appropriate type of oil until the oil level
is at the proper level. SAE 10w-30 oil is recommended for
general use.
Low Idle Switch
1. Turn the low idle Switch ON to limit noise and fuel consumption
for lighter generator loads.
2. Switch low idle OFF to operate engine at full speed when:
• Starting the generator
• A heavy load is applied
Voltage Selector
The Voltage Selector allows more current to be available at 120V
outlets if 240V output is not required:
Place switch at 120V only - only 120V outlets can be used.
Place switch at 120/240V: Both 120V and 240V outlets can be
used.
NOTE: Do not change the switch while under load. For parallel
function, switch position must be at 120/240V.
Stop The Engine
1. Turn off and unplug all connected electrical loads. Never start
or stop the generator with electrical devices plugged in or
turned on.
2. Push and hold the ON/OFF button for one second or push STOP
on the remote start key fob for one second.
3. Turn the main switch down to the off position.
4. Turn the fuel selector knob to the off position.
Do not run the engine with too little oil. Engine will shut off if
engine oil level is too low.
NOTICE
MAIN SW.
ON
OFF

Questions and Answers: