Model No. PGDA70BiSCO
7250 Watt Dual Fuel Inverter Generator
OPERATOR’S MANUAL
Warning: The Engine Exhaust from this product contains chemicals known to
the State of California to cause cancer, birth defects or other reproductive harm.
support@pulsar-products.com
866-591-8921
STOP
DO NOT RETURN TO STORE!
HAVE QUESTIONS OR NEED SERVICE?
PROTEION AGAIN RBON MONOXIDE
CO
SENTRY
VOLTAGE
120V
ONLY
120/
240V

Questions and Answers

  • S
    Sara MarshAug 14, 2025
    Why does my Pulsar Portable Generator engine stop suddenly?
    • J
      Joann ParsonsAug 14, 2025
      If your Pulsar Portable Generator engine stops suddenly, first, add engine oil to the correct level, remembering to check it before each use. If the fuel tank is empty or contains impure or low-quality gasoline, fill it with fresh 87+ octane stabilizer-treated unleaded gasoline, avoiding gasoline with more than 10% ethanol. A defective fuel tank cap can also create a vacuum, so test or replace it. Other potential causes include a faulty magneto (have a qualified technician service it) or a disconnected spark plug cap (secure the cap).
  • D
    Dwayne EllisAug 17, 2025
    What to do if the device attached to my Pulsar Portable Generator doesn't have power?
    • G
      Gabriel DavenportAug 17, 2025
      If the attached device doesn't have power when using your Pulsar Portable Generator, first ensure the device is properly plugged in. If it is, check if the circuit breaker has tripped; if so, turn off and unplug the device, reset the circuit breaker, then plug the device back in and turn it on. If the problem persists, the product may need to be repaired.
  • E
    Emily CooperAug 20, 2025
    Why is my Pulsar PGDA70BiSCO engine misfiring?
    • K
      Karen BarnesAug 21, 2025
      If your Pulsar Portable Generator engine misfires, check the spark plug cap and wire connections to ensure they are secure. Re-gap or replace the spark plug if it's damaged or has an incorrect gap. If the spark plug cap is defective, replace it. Use only fresh 87+ octane stabilizer-treated unleaded gasoline, avoiding gasoline with more than 10% ethanol. Diagnose and repair compression issues, referring to the 'Engine will not start: COMPRESSION RELATED' section.
  • E
    Erin JeffersonAug 25, 2025
    Why is my Pulsar PGDA70BiSCO engine knocking?
    • H
      Heather JohnsonAug 25, 2025
      If your Pulsar Portable Generator engine knocks, fill the fuel tank with fresh 87+ octane stabilizer-treated unleaded gasoline, ensuring not to use gasoline with more than 10% ethanol. Avoid exceeding the equipment's load rating. If the issue persists, have a qualified technician diagnose and service the engine for potential problems such as incorrect spark timing, deposit buildup, or a worn engine.
  • T
    Tiffany GilbertAug 27, 2025
    What to do if my Pulsar PGDA70BiSCO Portable Generator won't start and I suspect a compression problem?
    • J
      Jason GarciaAug 27, 2025
      If the Pulsar Portable Generator engine will not start due to compression issues, pour a tablespoon of oil into the spark plug hole, crank the engine a few times, and try to start it again. Tighten or replace the spark plug if it's loose or broken. If the problem continues, have a qualified technician service the cylinder head for potential issues like a loose cylinder head or damaged head gasket, or adjust/repair valves and tappets if they are misadjusted or stuck.
  • L
    Lisa ValenciaAug 30, 2025
    Why does my Pulsar PGDA70BiSCO engine backfire?
    • M
      Marie BrownAug 30, 2025
      If your Pulsar Portable Generator engine backfires, fill the fuel tank with fresh 87+ octane stabilizer-treated unleaded gasoline, avoiding gasoline with more than 10% ethanol. Use cold weather fuel and oil additives if the engine is too cold. If the issue persists, have a qualified technician diagnose and service the engine for potential problems such as a stuck intake valve or an overheated engine. Also, check the engine timing.
  • S
    Sharon HarrisSep 3, 2025
    What to do if my Pulsar PGDA70BiSCO engine stops when under a heavy load?
    • W
      William CooperSep 3, 2025
      If your Pulsar Portable Generator engine stops when under a heavy load, clean the air filter element. Allow the engine to warm up prior to operating equipment.
  • R
    Ryan BellSep 6, 2025
    What should I do if I have engine oil problems with my Pulsar Portable Generator?
    • R
      Rachel Grant DDSSep 6, 2025
      If you have engine oil related issues with your Pulsar Portable Generator, fill the engine oil to the proper level, checking it before every use. Ensure the engine is operated on a level surface to prevent triggering the low oil shutdown. Always check the engine oil level.
  • W
    wardstaceySep 9, 2025
    How do I fix a spark arrestor clogged with soot on my Pulsar PGDA70BiSCO?
    • E
      Eric BrownSep 9, 2025
      If the spark arrestor is clogged with soot in your Pulsar Portable Generator, clean and replace it.

Summary

Introduction to the Generator Manual

Safety Definitions Explained

Defines key safety terms like DANGER, WARNING, CAUTION, and NOTICE.

Understanding Safety Symbols

Explains the meaning and importance of the safety alert symbol.

Safety Warnings and Notices

Save This Manual For Future Reference

Emphasizes reading the manual for safe operation, maintenance, and storage.

Safety Instructions and Precautions

General Safety Precautions

Covers critical hazards like carbon monoxide, electrocution, and fire.

Safety Alerts and Symbols Identification

Explains various hazard symbols and their associated risks.

Safe Operation Practices

Correct Usage Guidelines

Proper placement and exhaust direction to avoid carbon monoxide.

Incorrect Usage Locations

Lists prohibited areas for generator operation.

Fuel Handling Safety

Precautions regarding the flammability of gasoline and its vapors.

Equipment Operation Safety

Safety guidelines for starting and operating the generator.

Generator Safety Features

Parallel Kit Safety Precautions

Guidelines for safely connecting two generators using a parallel kit.

Carbon Monoxide (CO) Safety

Information on carbon monoxide hazards and detection.

CO Sentry System Operation

Details the CO detection and automatic shutoff system.

Generator Components Overview

Control Panel Identification

Identifies the main interface and controls of the generator.

Engine and Fuel System Parts

Locates key components like the spark plug, fuel cap, and carburetor.

Generator Housing and Accessories

Identifies exterior covers, air filter, battery, and exhaust.

Control Panel Layout and Functions

Main Controls and Indicators

Describes switches for main power, low idle, reset, fuel, and voltage.

Digital Display Center Explanation

Explains the information shown on the digital display.

AC Outlet Descriptions

Details the available AC power outlets and their ratings.

CO Sentry Indicator Light

Explains the function of the carbon monoxide detection indicator.

Generator Specifications

Engine Specifications

Details engine type, displacement, compression, and power output.

Generator Electrical Specifications

Lists rated power, voltage, frequency, and phase.

Physical Specifications

Provides dimensions and net weight of the generator.

Preparation and Initial Setup

Unpacking and Assembly Steps

Instructions for removing the generator from packaging and initial setup.

Adding Engine Oil Procedure

Step-by-step guide and safety precautions for filling engine oil.

Adding Gasoline Procedure

Instructions and warnings for fueling the generator with gasoline.

Connecting LPG Tank

Guidelines for connecting a propane tank for fuel.

Advanced Preparation Steps

Propane Tank Handling and Safety

Safety notices and connection procedures for propane tanks.

Connecting the Battery

Step-by-step instructions for connecting the generator's battery.

Grounding the Generator

Instructions and safety warning for proper electrical grounding.

Generator Operation Guide

Generator Location Requirements

Specifies safe placement for ventilation and carbon monoxide prevention.

Starting the Generator

Step-by-step instructions to start the generator engine.

Operating the Generator

Generator Starting Methods

Explains Recoil, Push-Button, and Remote Start options.

Connecting Electrical Loads

How to connect devices and what to expect with electrical loads.

Fuel Switching Procedure

Transitioning between Gasoline and LPG fuel sources.

Parallel Operation

Information on connecting multiple generators for increased power.

Overload Indicator Function

Explains the purpose and behavior of the overload warning light.

Operational Adjustments

Low Idle Switch Function

Using the low idle switch for noise and fuel efficiency.

Voltage Selector Usage

How to adjust voltage output for different power needs.

Understanding Generator Capacity

Generator Wattage Limits

Guidance on determining and staying within the generator's capacity.

Wattage Reference Example

Example calculation for appliance power requirements.

Maintenance Schedule and Procedures

Maintenance Schedule Overview

Summary of recommended maintenance intervals for various tasks.

Power System Maintenance

Covers cleaning, checking oil, and air filter maintenance.

Engine Component Maintenance

Details spark plug, spark arrestor, and idle speed checks.

Fuel and Oil Maintenance

Fuel System Checks and Filling

Safety and procedures for checking and fueling the generator.

Engine Oil Change Procedure

Step-by-step guide for performing an engine oil change.

Spark Plug, Filter, and Arrestor Maintenance

Air Filter Maintenance

Instructions for cleaning or replacing the air filter element.

Spark Arrestor Maintenance

Procedure for cleaning the spark arrestor and associated safety.

Spark Plug Maintenance

Steps for inspecting, cleaning, and replacing the spark plug.

Storage and Fuel System Care

Preparing for Long-Term Storage

Steps for cleaning and preparing the generator for storage.

Fuel Tank and Carburetor Maintenance

Procedures for fuel treatment, draining, and carburetor care.

Troubleshooting Common Issues

Engine Will Not Start

Causes and solutions for engine startup problems.

Ignition (Spark) Related Issues

Troubleshooting problems related to the ignition system.

Troubleshooting Engine Problems

Compression Related Issues

Solutions for problems related to engine compression.

Engine Oil Related Issues

Troubleshooting steps for low oil shutdown.

Spark Arrestor Issues

Solutions for a clogged spark arrestor.

Advanced Troubleshooting

Engine Stops Suddenly

Diagnosing and resolving unexpected engine shutdowns.

Engine Stops Under Heavy Load

Troubleshooting performance issues when under load.

Engine Knocks

Causes and solutions for engine knocking.

Engine Backfires

Addressing engine backfiring issues.

Troubleshooting Device Connectivity

Attached Device Has No Power

Solutions when connected devices are not receiving power.

Pulsar PGDA70BiSCO Specifications

General IconGeneral
ModelPGDA70BiSCO
Fuel TypeGasoline/Propane
Engine Type4-Stroke OHV
Cooling SystemAir Cooled
Starting Power9000W (Gasoline), 8100W (Propane)
Starting Watts9000W (Gasoline), 8100W (Propane)
Running Watts7000W (Gasoline), 6300W (Propane)

Related product manuals