1.SAVETHESEINSTRUCTIONS–Thismanualcontainsimportantsafetyandoperatinginstructionsforyour
batterycharger
2.UseofanattachmentnotrecommendedorsoldbyPulseTechProductsmayresultinariskoffire,elec-
tricshock,orinjurytopersons.
3.Toreduceriskofdamagetoelectricplugandcord,pullbyplugratherthancordwhendisconnecting
charger.
4.Anextensioncordshouldnotbeusedunlessabsolutelynecessary.Useofimproperextensioncordcould
resultinariskoffireandelectricshock.Ifextensioncordmustbeused,makesure:
a)Thepinsontheplugoftheextensioncordarethe
samenumber,sizeandshapeasthoseoftheplugonthe
charger.
b)Theextensioncordisproperlywiredandingoodelec-
tricalcondition;and
c)ThewiresizeislargeenoughforACampereratingof
thechargerasspecified:
Lengthofcord(ft): 25 50 100 150
AWGsizeofcord: 18 18 18 16
5.Donotoperatethechargerwithdamagedcordorplug–replacethecordorplugimmediately.
6.Donotoperatechargerifithasreceivedasharpblow,beendropped,orotherwisedamagedinanyway.
Takeittoaqualifiedservicetechnician.
7.Donotdisassemblecharger;takeittoaqualifiedtechnici anwhenserviceorrepairisrequired.Incorrect
reassemblymayresultinariskofelectricshockorfire.
Safety Instructions
Fig. A Fig. B Fig. C
5
Battery Type Phase Timeout
AGM and STD
Soft Start or Bulk 31.5 hours/max
Absorption 12 hours/max
Recovery(Battery repair) 6 hours/max
Float 4 hours
LiFePO4
Soft Start 2 hours/max
Bulk 10 hours/max
Absorption 12 hours/max
XC450-TIMEOUT TABLE
≤6.3V(6Vmode),andforLiFePO4batteries:Whenthebatteryvoltageis at ≤13.1V.After
reachingthesethresholds,rechargeshouldbeinitiatedaccordingtothesetchargingmode.
8.IftheACisdisconnected:
a.Iftheclampsarenotremoved,andtheACisreconnected,thenitwillchargewiththe
originalsetting(CHARGING”isflashing,andthelightofselectedchargingmodeis flashing,
plus“PULSING”isflashing.).
b.Iftheclampsareremoved,and theAC isreconnected, thechargerwillreturn tothe
defaultstate,whichis12V/STD.