Configuration-Kodak
1. Long press Enter to Menu,
choose the suitable working
mode.
If you apply “USB” or “SOL
setting.
2. Choose PYLON in the
5
th
setting
3. Select suitable
frequency in the 9
th
setting
4. If you apply “SBU” mode,
except for the first 3 steps, the
11
th
setting, the maximum
charge current from grid should
be set according to battery
numbers.
5. The 12
th
setting, discharge
voltage limit could be set at 46V.
6. The 13
th
setting, charge
voltage limit could be set at 53V.