Power and Battery Connections for the PCXL
Panel power supply input Nominal Range
Mains Supply Voltage AC 230 Vac at 50 Hz -15% +10%
Transformer Rating PCX L 45 VA 18.5 V at 2.5 A
Panel power supply output Nominal Range
Output voltage 13.7 Vdc 10 - 15 Vdc
Output Current PCX L 1.5 A continuous 2.0 A peak, during battery charging
Power Supply Type A.
Battery charging specification
Float voltage 13.8 Vdc
Battery low voltage cut-off 10.5 V
Recharge time < 24 hours
Control panel type
Standby battery capacity current 300 mA (3 Ah to 6 Ah)
Standby battery capacity current 700 mA (7 Ah to 17 Ah)