Event
SIA
code
CID
code
Event
Type
Number
Default 1
(ARC) Full
Reporting
Default 2
(ARC) No
Arm/Disarm
Default 3 (ARC) No
Arm/Disarm and
Alarm Restorals
Default
(SMS)
SUBAREA / SHUNT ARM/DISARM
Sub-Area Arm CG 3402 4
ü û û û
Shunt Closed 1402 4
Sub-Area Disarm OG 1402 5
Shunt Opened 3402 5
BURGLARY ALARM
Burglary Alarm BA 1130 7
All All All Once
Gas Alarm GA 1151 7
Entry/Exit alarm BA 1134 7
No Zone Activity
- Sent
NA 1680 7
24h Alarm BA 1133 7
Perimeter Alarm BA 1131 7
Keybox/Guard
Zone Alarm
1250 7
Flood Alarm WA 1154 7
Interior Alarm BA 1132 7
BURGLARY RESTORE
Burglary Restore BH 3130 9
All All
û û
Gas Restore GH 3151 9
Entry/Exit
Restore
BH 3134 9
Day Alarm
Restore
BH 3133 9
Interior Alarm
Restore
BH 3132 9
Perimeter
Restore
BH 3131 9
Keybox Restore 3250 9
Flood Alarm
Restore
WH 3154 9
Ward Alarm
Restore
BH 3130 9
FIRE ALARM
Fire Alarm FA 1110 10
ü ü ü ü
Fire Key Pressed FA 1110 10
FIRE ALARM RESTORE
Fire Alarm
Restore
FH 3110 11
ü ü û û
Fire Key Restore FH 3110 11
PCX Installation Guide 102017852 - V01 91