User Manual Ultra
Version M | # DOC00040 April 22, 2012

Questions and Answers

  • C
    Cynthia JohnsonSep 23, 2025
    What does voltage over setting mean on Quantel Ultra ICE 450 Measuring Instruments?
    • V
      Vicki MitchellSep 23, 2025
      This indicates a problem with the charging system, which is a potentially serious safety issue. Contact Quantel Customer Service.
  • G
    Gregory PhillipsAug 25, 2025
    What to do if Quantel Ultra ICE 450 Measuring Instruments show low coolant level?
    • A
      abellAug 25, 2025
      If the Quantel Measuring Instruments system is low on coolant, ensure it is properly filled after draining. Refer to the instructions in Maintenance on page 68.
  • C
    Carl EspinozaAug 25, 2025
    What to do if Quantel Ultra ICE 450 Measuring Instruments display charger/simmer over temp?
    • K
      Kristen WestAug 26, 2025
      If the charger inductor is too hot, turn OFF power to the ICE450 and allow it to cool. Make sure that airflow is not obstructed at the front or back of the ICE450. If the interlock condition persists, there may be a problem with the charger circuitry. In this case, contact Quantel Customer Service.
  • J
    Jonathan MyersAug 26, 2025
    Why is the coolant temperature high in my Quantel Ultra ICE 450 Measuring Instruments?
    • K
      karen98Aug 27, 2025
      If the coolant is too warm for proper operation, turn off the ICE450 and allow it to cool. The high-temperature setting may need to be increased, or the cooling fans may have failed. Contact Quantel Customer Service for these issues.
  • B
    Benjamin NorrisAug 27, 2025
    What causes low coolant temperature in Quantel Ultra ICE 450 Measuring Instruments?
    • R
      Regina BarryAug 27, 2025
      If the coolant is not warm enough for proper operation, allow time for the coolant to warm. The low-temperature setting may need to be reduced, or the heater minimum power setting may need adjustment. The heater circuit may have failed. Contact Quantel Customer Service for these issues.
  • T
    Terry ConradSep 14, 2025
    Why is there no system power in my Quantel Ultra ICE 450?
    • R
      Randy BarreraSep 14, 2025
      If there is no power connected, check the simple things first—make sure the power cord is plugged into the outlet and making connection to the back of the ICE.
  • E
    Eric PenaSep 12, 2025
    How to resolve flashlamp disabled time out delay expired on Quantel Measuring Instruments?
    • R
      Richard TaylorSep 12, 2025
      If the flashlamp timeout has expired, disable timeouts or change the flashlamp timeout to 00:00.
  • A
    Andrea DavidsonSep 13, 2025
    What to do if simmer disabled time out delay expired on Quantel Ultra ICE 450 Measuring Instruments?
    • M
      Michele LeeSep 13, 2025
      If the simmer timeout has expired, you should not attempt to repair this problem. Contact Quantel Customer Service for repair.
  • G
    Gregory SmithSep 4, 2025
    What to do if Quantel Ultra ICE 450 Measuring Instruments show defective temp. sensor error?
    • J
      John HowellSep 5, 2025
      If one or more of the three feedback thermistor circuits (coolant, charger/ simmer, and harmonic generator) is faulty or is running too cold, ensure all temperatures are above 18 °C. If the system does not include a harmonic generator, make sure the HG option is turned off from the System Info menu.
  • A
    Alyssa MooreSep 2, 2025
    How to fix power too high error in Quantel Measuring Instruments?
    • I
      iweberSep 2, 2025
      If the voltage or frequency settings are too high, resulting in power too high, reduce voltage, energy, or frequency until the power is less than 450W. Verify this and save the configuration.

Summary

LASER SAFETY

Hazard Information

Explains hazard terms, symbols, and instructions for safe laser use.

Terms & Warning Symbols

Details hazard symbols and their meanings for safe operation.

General Hazards

Details general hazards and unsafe practices associated with laser use.

Other Hazards

Lists typical hazards associated with the product and its handling.

Safe Operation of the Laser

Outlines essential safety procedures for operating the laser system correctly.

SETUP

Mounting the Laser Head

Instructions for securing the Laser Head to a flat mounting surface.

Connecting Standard Upright System

Step-by-step guide for connecting the standard upright Ultra System components.

Connecting a Rack ICE450

Instructions for connecting the components of a rack-mounted Ultra System.

Filling the Standard ICE450

Detailed procedure for filling the coolant reservoir of the standard ICE450 unit.

Filling the Rack ICE450

Detailed procedure for filling the coolant reservoir of the rack-mounted ICE450 unit.

FUNCTIONS

ICE450 Front Panel Controls

Describes the functions of the ICE450 front panel controls and indicators.

OPERATION

Safety and Precautions

General safety precautions and guidelines to prevent system damage.

Remote Box Controls and Navigation

Details the Remote Box buttons, navigation, and basic menu structure.

Remote Box Menu Descriptions

Provides detailed explanations of the Remote Box menu items.

Example Start-Up Procedure

Step-by-step guide for starting the laser system.

Shutdown Procedure

Procedure for safely shutting down the laser system.

SOFTWARE

Serial Interface Configuration

Information on the RS-232 serial interface for system control and communication.

TECHNICAL SPECIFICATIONS

OPTIONAL EQUIPMENT

MAINTENANCE

Draining the ICE450

Step-by-step guide for completely draining the ICE450 coolant.

Draining a Rack ICE450

Procedure for completely draining the coolant from a rack-mounted ICE450.

Flashlamp Replacement

Procedure for replacing the flashlamp for optimal performance.

TROUBLESHOOTING

Resolving Interlock Fault Conditions

Provides solutions for common interlock fault conditions and their causes.

Serial Communications Troubleshooting

Troubleshooting steps for serial communication issues with the ICE450.

Diagnosing Common Problems

Guide to diagnosing general system problems and their potential causes.

Quantel Ultra ICE 450 Specifications

General IconGeneral
CategoryMeasuring Instruments
Frame GrabberYes
DisplayLCD
Weight2.5 kg
Power Supply100-240 VAC, 50/60 Hz
Dimensions300 x 200 x 100 mm

Related product manuals