LTE  Module  Series 
  LTE  OPEN  EVB  User  Guide 
 
LTE_OPEN_EVB_User_Guide                                                                                          12 / 62 
 
   
 
 
 
 
1. 
1) 
VBAT (T0104) is a test point on LTE OPEN EVB, and is used to test the current of the modules. If it 
is used to supply power for the modules, then R0106 should be disconnected.   
2. 
2) 
The maximum baud rate is limited to the RS232 level shifter chip on the EVB. For the maximum 
baud rates supported by the modules, please refer to their respective hardware designs.   
Five Switches:   
  Power Switch (S0301) for VBAT ON/OFF control   
  SDC1 function switch (S0201) for switching between GPIO and Wi-Fi 
function.   
  SDC2 function switch (S0701) for switching between SD and eMMC 
functions.   
  PCM function switch (S1001) for switching between BT and codec 
functions.   
  Switch S0401 reserved for internal testing. 
Two Buttons: 
  PWRKEY (S0403) for turning on/off LTE-QuecOpen modules 
  RESET (S0402) for resetting LTE-QuecOpen modules 
Size: 200.0mm × 145.0mm × 1.6mm