6.3 Oil specifications
Never mix oils of different brands or types as they may not be compatible and the oil mix
will have inferior properties. A label, indicating the type of oil filled ex-factory, is stuck on
the air receiver/oil tank.
It is strongly advised to use the recommended lubricants. See section Preventive maintenance
schedule for recommended oil change intervals.
For part numbers, consult the Spare Parts List.
Quinsyn Plus Fluid
Quinsyn Plus Fluid is a high quality synthetic lubricant for oil-injected screw compressors which
keeps the compressor in excellent condition. Because of its excellent oxidation stability, Quinsyn
Plus Fluid can be used for compressors operating at ambient temperatures between 0 ˚C (32 ˚F)
and 46 ˚C (115 ˚F).
6.4 Oil, filter and separator change
Important
Never mix oils of different brands or types. A label, indicating the type of oil filled ex-
factory, is stuck on the air receiver/oil tank.
Always drain the compressor oil at all drain points. Used oil left in the compressor can
shorten the lifetime of the new oil.
If the compressor is exposed to external pollutants, is being used at high temperatures
(oil temperature above 90˚C / 194˚F) or is being used under severe conditions, it is
advised to change the oil more frequently. Consult your supplier.
Instruction book