D6500 Computer Interface Manual
74-05313-000-G 10/16/97 Page 25 © 1988-1997 Radionics, Inc.
Automation Output
Signal D6500 Internal/External Printer D6500 Mode SIA Mode Notes
D7112 and D9112B Other Reports – Modem II (continued)
Phone Line 1 Fail dd/dd tt:tt ql ACCT aaaa PHONE LINE FAIL h1rrlssssssaaaasTsssBt <header>[#aaaa|
N
LT1]
D7112
+++ ACCT aaaa PHONE LINE=1
Phone Line 2 Fail dd/dd tt:tt ql ACCT aaaa PHONE LINE FAIL h1rrlssssssaaaasTsssCt <header>[#aaaa|
N
LT2]
D7112
+++ ACCT aaaa PHONE LINE=2
Phone Line 1 Restoral dd/dd tt:tt ql ACCT aaaa PHONE RESTORAL h1rrlssssssaaaasRsssBt <header>[#aaaa|
N
LR1]
D7112
+++ ACCT aaaa PHONE LINE=1
Phone Line 2 Restoral dd/dd tt:tt ql ACCT aaaa PHONE RESTORAL h1rrlssssssaaaasRsssCt <header>[#aaaa|
N
LR2]
D7112
+++ ACCT aaaa PHONE LINE=2
SDI Fail dd/dd tt:tt ql ACCT aaaa SDI FAILURE h1rrlssssssaaaasTsssDt <header>[#aaaa|
Npi
dddET]
+++ ACCT aaaa SDI=ddd
SDI Restoral dd/dd tt:tt ql ACCT aaaa SDI RESTORAL h1rrlssssssaaaasRsssDt <header>[#aaaa|
Npi
dddER]
+++ ACCT aaaa SDI=ddd
Point Bus Fail dd/dd tt:tt ql ACCT aaaa PT BUS TROUBLE h1rrlssssssaaaasTsssDt <header>[#aaaa|
N
ET]
Point Bus Restoral dd/dd tt:tt ql ACCT aaaa PT BUS RESTORAL h1rrlssssssaaaasRsssDt <header>[#aaaa|
N
ER]
AC Fail dd/dd tt:tt ql ACCT aaaa AC FAILURE h1rrlssssssaaaasPsssst <header>[#aaaa|
N
AT]
AC Restoral dd/dd tt:tt ql ACCT aaaa AC RESTORAL h1rrlssssssaaaasRsss0t <header>[#aaaa|
N
AR]
Battery Missing dd/dd tt:tt ql ACCT aaaa BATTERY MISSING h1rrlssssssaaaasTsss9t <header>[#aaaa|
N
YM]
Battery Low dd/dd tt:tt ql ACCT aaaa BATTERY LOW h1rrlssssssaaaasTsss9t <header>[#aaaa|
N
YT]
Battery Restoral dd/dd tt:tt ql ACCT aaaa BATTERY RESTORE h1rrlssssssaaaasRsss9t <header>[#aaaa|
N
YR]
Watchdog Reset dd/dd tt:tt ql ACCT aaaa WATCHDOG RESET h1rrlssssssaaaasNsD09t <header>[#aaaa|
N
YW]
Remote Reset dd/dd tt:tt ql ACCT aaaa REMOTE RESET h1rrlssssssaaaasNsD11t <header>[#aaaa|
N
RN]
D9112