Contact-ID Event Code Classifications
The Event codes have been grouped according to the type of event, as described below.
Alarms System Troubles Sensor Troubles
100 Medical 300 System trouble 380 Sensor trouble
101 Pendant transmitter 301 AC loss 381 Loss of supr. - RF
102 Fail to report 302 Low system battery 382 Loss of supr. RPM
110 Fire alarm 303 RAM checksum bad 383 Sensor tamper
111 Smoke 304 ROM checksum bad 384 RF Xmtr. low battery
112 Combustion 305 System reset 385 Smoke det. Hi sensitivity
113 Water flow 306 Panel program changed 386 Smoke det. Low sensitivity
114 Heat 307 Self-test fail 387 Detector Hi sensitivity
115 Pull Station 308 System shutdown 388 Detector Low sensitivity
116 Duct 309 Battery test fail
117 Flame 310 Ground fault
O/C Remote Access
118 Near alarm 400 Open/Close
120 Panic alarm
Sounder/Relay Troubles
401 O/C by user
121 Duress 320 Sounder/relay trouble 402 Group O/C
122 Silent 321 Trouble bell 1 403 Automatic O/C
123 Audible 322 Trouble bell 2 404 Late to O/C
130 Burglary 323 Trouble alarm relay 405 Deferred O/C
131 Perimeter 324 Trouble relay 406 Cancel
132 Interior 325 Reversing relay 407 Remote arm/disarm
133 24 Hour 408 Quick arm
134 Entry/Exit
System and Peripheral Troubles
409 Keyswitch O/C
135 Day/Night 330 System peripheral
136 Outdoor 331 Polling loop open
Remote Access
137 Tamper 332 Polling loop short 411 Callback request
138 Near alarm 333 Expander module failure 412 Success - download access
139 Intrude verify 334 Repeater failure 413 Unsuccessful access
140 General alarm 335 Local printer paper out 414 System shutdown
141 Polling loop open 336 Local printer out 415 Dialer shutdown
142 Polling loop short 337 Exp. module DC loss
143 Expansion module fail 338 Exp. module low batt.
Access Control
144 Sensor tamper 339 Exp. module reset 421 Access denied
145 Expansion module tamper 341 Exp. module tamper 422 User access gained
146 Silent burglary 441 Armed stay
150 24 hour non-burg
Communication Troubles
450 Exception O/C
151 Gas detected 350 Communication trouble 451 Early to O/C
152 Refrigeration 351 Telco line fault 1 452 O/C late
153 Loss of heat 352 Telco line fault 2 453 Failed to open
154 Water leakage 353 Long range radio Xmit fault 454 Failed to close
155 Foil break 354 Communication failure 455 Auto-arm failed
156 Day trouble 355 Loss of radio supervision 456 Partial arm
157 Low bottled gas level 356 Loss of central polling 457 Exit error
158 High temperature 357 Radio VSWR trbl. 458 User on premise
159 Low temperature 459 Recent close
161 Air flow loss
Protection Loop Troubles
370 Protection loop
Supervisory
371 Protection loop open
200 Fire supervisory 372 Protection loop short
201 Low water pressure 373 Fire trouble
202 Low CO
2
374 Exit error (zone)
203 Gate valve sensor
204 Low water level
205 Pump activated
206 Pump failure

Table of Contents