Modem IIIa
2TM
Messages for the D7212, D7412, D9112, D9124 and D9412 Control/Communicators
D6500 Computer Interface Manual
74-05313-000-G 10/16/97 Page 45 © 1988-1997 Radionics, Inc.
Signal Internal/External Printer 6500 Output Mode SIA Output Mode
Door Secured
dd/dd tt:tt ql ACCT aaaa DOOR SECURED
h1rrlssssssaaaaASspppt <header>[#aaaa|NriaDCppp]
(Automatic)
+++ ACCT aaaa AUTOMATIC
+++ ACCT aaaa AREA=a POINT=ppp
Door Secured
dd/dd tt:tt ql ACCT aaaa DOOR SECURED
h1rrlssssssaaaaASspppt <header>[#aaaa|Nria/idiiiDCppp]
(By User)
+++ ACCT aaaa BY USER
+++ ACCT aaaa AREA=a ID-iii POINT=ppp
Door Unlocked
dd/dd tt:tt ql ACCT aaaa DOOR UNLOCKED
h1rrlssssssaaaaAUspppt <header>[#aaaa|NriaDOppp]
+++ ACCT aaaa AREA=a POINT=ppp
Door Unlocked
dd/dd tt:tt ql ACCT aaaa DOOR UNLOCKED
h1rrlssssssaaaaAUspppt <header>[#aaaa|NriaDOppp]
(Automatic)
+++ ACCT aaaa AUTOMATIC
+++ ACCT aaaa AREA=a POINT=ppp
Door Unlocked
dd/dd tt:tt ql ACCT aaaa DOOR UNLOCKED
h1rrlssssssaaaaAUspppt <header>[#aaaa|Nria/idiiiDOppp]
(By User)
+++ ACCT aaaa BY USER
+++ ACCT aaaa AREA=a ID=iii POINT=ppp
Duress
dd/dd tt:tt ql ACCT aaaa DURESS
h1rrlssssssaaaasDsiiit <header>[#aaaa|Nria/idiiiHA]
+++ ACCT aaaa AREA=a ID=iii
Extend Close Time by Area
dd/dd tt:tt ql ACCT aaaa EXTN CLOSE TIME
h1rrlssssssaaaasTsD26t <header>[#aaaa|Nria/idiii/tihh:mmCE]
+++ ACCT aaaa AREA=a ID=iii TIME=hh:mm
Extra Point
dd/dd tt:tt ql ACCT aaaa EXTRA POINT
h1rrlssssssaaaasTspppt <header>[#aaaa|NriaXEppp]
+++ ACCT aaaa AREA=a POINT=ppp
Fail To Call RAM
dd/dd tt:tt ql ACCT aaaa BAD CALL TO RAM
h1rrlssssssaaaasTsF02t <header>[#aaaa|NRA]
Fail To Close by Area
dd/dd tt:tt ql ACCT aaaa FAIL TO CLOSE
h1rrlssssssaaaasTsssEt <header>[#aaaa|NriaCI]
+++ ACCT aaaa AREA=a
Fail To Execute
dd/dd tt:tt ql ACCT aaaa FAIL TO EXECUTE
h1rrlssssssaaaasNsD35t <header>[#aaaa|NriaDKppp]
(Door Unlocked-Interlock)
+++ ACCT aaaa DOOR UNLOCKED-INTERLOCK
+++ ACCT aaaa AREA=a POINT=ppp