SPECIAL CONDITIONS FOR SAFE USE
1. The PGM-62xx shall only be fitted with
RAE Systems Battery Pack type M01-
3051-000 or M01-3053-000 or Battery
Adapter M01-3052-000 or M01-3054-000
fitted with Duracell MN1500 batteries.
2. The PGM-62xx shall only be charged
outside hazardous areas.
No precautions against electrostatic discharge
are necessary for portable equipment that has
an enclosure made of plastic, metal, or a
combination of the two, except where a
significant static-generating mechanism has
been identified. Activities such as placing the
item in a pocket or on a belt, operating a
keypad or cleaning with a damp cloth, do not
present a significant electrostatic risk.
However, where a static-generating mechanism
is identified, such as repeated brushing against
clothing, then suitable precautions shall be
taken, e.g., the use of anti-static footwear.
Note: Users are recommended to refer to ISA-
RP12.13, Part II-1987 for general information
on installation, operation, and maintenance of
combustible gas detection instruments.
The MultiRAE multi-gas detector must be
calibrated if it does not pass a bump test, or at
least once every 180 days, depending on use
and sensor exposure to poisons and
contaminants.
HAZARDOUS LOCATION APPROVALS
Exia Class I, Division 1, Groups A, B, C, D, T4
SIRA 11ATEX2152X, 0575 II 1G Ex ia IIC T4 Ga
(for PGM62x0/PGM62x6)
SIRA 11ATEX2152X, 0575 II 2G Ex ia d IIC T4 Gb
(for PGM62x8)
UM = 20V
IECEx SIR 11.0069X, Ex ia IIC T4 Ga (for
PGM62x0/PGM62x6)
IECEx SIR 11.0069X, Ex ia d IIC T4 Gb (for
PGM62x8)
WIRELESS CERTIFICATION
Complies with the following:
FCC Part 15
R&TTE Directive (1999/5/EC)
WARNINGS
ANY RAPID UP-SCALE READING FOL-
LOWED BY A DECLINING OR ERRATIC
READING MAY INDICATE A GAS CONCEN-
TRATION BEYOND UPPER SCALE LIMIT,
WHICH MAY BE HAZARDOUS.
TOUTE LECTURE RAPIDE ET POSITIVE,
SUIVE D’UNE BAISSE SUBITE AU
ERRATIQUE DE LA VALEUR, PEUT
INDIQUER UNE CONCENTRATION DE GAZ
HORS GAMME DE DÉTECTION QUI PEUT
ÊTRE DANGEREUSE.
ONLY THE COMBUSTIBLE GAS DETECTION
PORTION OF THIS INSTRUMENT HAS BEEN
ASSESSED FOR PERFORMANCE.
UNIQUMENT, LA PORTION POUR
DÉTECTOR LES GAZ COMBUSTIBLES DE
CET INSTRUMENT A ÉTÉ ÉVALUÉE.
CAUTION: HIGH OFF-SCALE READINGS
MAY INDICATE AN EXPLOSIVE
CONCENTRATION.
ATTENTION: DES LECTURES HAUTES ET
HORS DECHELLE PEUVENT INDIQUER
DES CONCENTRATIONS DE GAZ
INFLAMMABLES.
CAUTION: SUBSTITUTION OF COMPO-
NENTS MAY IMPAIR INTRINSIC SAFETY.
CAUTION: BEFORE EACH DAY’S USAGE,
SENSITIVITY OF THE LEL SENSOR MUST BE
TESTED ON A KNOWN CONCENTRATION OF
METHANE GAS EQUIVALENT TO 20 TO 50% OF
FULL-SCALE CONCENTRATION. ACCURACY
MUST BE WITHIN 0 AND +20% OF ACTUAL.
ACCURACY MAY BE CORRECTED BY
CALIBRATION PROCEDURE.
ATTENTION: AVANT CHAQUE UTILISATION
JOURNALIERE, VERIFIER LA SENSIBILITE DU
CAPTEUR DE LIE AVEC UNE CONCENTRATION
CONNUE DE METHANE EQUIVALENTE DE 20
A 50% DE LA PLEINE ECHELLE. LA PRECISION
DOIT ETRE COMPRISE ENTRE 0 ET 20% DE LA
VALEUR VRAIE ET PEUT ETRE CORRIGEE PAR
UNE PROCEDURE D’ETALONNAGE.
15.
16.
17.

Other manuals for Rae MultiRAE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rae MultiRAE and is the answer not in the manual?

Rae MultiRAE Specifications

General IconGeneral
Operating Temperature-20°C to 50°C (-4°F to 122°F)
Humidity0% to 95% relative humidity (non-condensing)
BatteryRechargeable Li-ion battery
VOC measurement range0-5000 ppm
SensorsPID, LEL, O2, CO, H2S
Battery LifeUp to 18 hours
DisplayBacklit LCD
Data LoggingYes
CommunicationWireless (optional), Bluetooth
AlarmsAudible, visual, and vibrating alarms
PumpInternal pump
CertificationsATEX, IECEx, UL, CSA

Related product manuals