Rae ToxiRAE Pro User Manual

Rae ToxiRAE Pro
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ToxiRAE Pro
User’s Guide
P/N G02-4009-000 Rev. C
March 2013

Table of Contents

Questions and Answers:

Rae ToxiRAE Pro Specifications

General IconGeneral
TypePortable Gas Detector
DisplayLCD with backlight
AlarmsVisual, audible, and vibrating alarms
Battery TypeRechargeable Lithium-ion battery
Sensor TypeElectrochemical
Gas DetectedVolatile Organic Compounds (VOCs)
Detection RangeVaries by gas type
Data LoggingYes
Battery LifeUp to 24 hours
Operating Temperature-20°C to 50°C (-4°F to 122°F)
Operating Humidity0 to 95% RH
ConnectivityUSB for data transfer
CertificationsATEX, IECEx, UL, CSA

Summary

Safety Warnings and Precautions

General Information

ToxiRAE Pro Specifications

Available Electrochemical Sensors

User Interface

Charging the ToxiRAE Pro

Turning the ToxiRAE Pro On

Turning the ToxiRAE Pro Off

Manually Testing Alarms

Operating the ToxiRAE Pro

Entering Programming Mode

Programming Menus

Alarm Setting Menu

High Alarm Settings

Procedure to set the High Alarm level for the ToxiRAE Pro.

Low Alarm Settings

Procedure to set the Low Alarm level for the ToxiRAE Pro.

Man Down Alarm Configuration

Setting up the Man Down Alarm feature, including its operation and notifications.

Datalog Settings

Monitor Setup

Wireless Setup

Configuration of wireless parameters like Radio On/Off, PAN ID, Channel, and Join Network.

Policy Enforcement

Setting Policy Enforcement

Procedures for configuring policy enforcement settings using ProRAE Studio II.

AutoRAE 2 Cradle Configuration

Specific steps for setting policy enforcement using the AutoRAE 2 Cradle.

Desktop Cradle/Travel Charger Configuration

Steps for setting policy enforcement using a desktop cradle or travel charger.

Policy Enforcement Options

Details on 'Must Calibrate' and 'Must Bump' options and their bypass settings.

Bump Testing & Calibrating

Bump Testing with AutoRAE 2

Instructions for bump testing and calibrating using the AutoRAE 2 Automatic Test and Calibration Station.

Functional Bump Testing

Steps for performing a functional bump test on the ToxiRAE Pro in Normal Mode.

Calibration Adapter

Connecting the Calibration Adapter

Step-by-step guide on how to connect the calibration adapter to the ToxiRAE Pro.

Zero Calibration

Span Calibration

Changing Span Gas Concentration

Steps to change the span gas concentration used for calibration.

Diagnostic Mode

Entering Diagnostic Mode

Steps to enter Diagnostic Mode, including password entry.

Alarm Signal Summary

Downloading Datalogs and PC Configuration

Maintenance

Replacing the Li-Ion Battery

Detailed steps for safely removing and replacing the ToxiRAE Pro's Li-ion battery.

Proper Battery Disposal

Information on the proper disposal of the product's battery according to WEEE directive.

Replacing the Sensor Module

Instructions for gently removing and installing a new sensor module, followed by calibration.

Troubleshooting

Technical Support

Appendix A: Regulatory Information

ToxiRAE Pro Marking and Certifications

Information on ToxiRAE Pro marking, IECEx, ATEX, CSA certifications, and operating conditions.