ToxiRAE Pro User’s Guide
7
2. Specifications
ToxiRAE Pro Specifications
Dimensions
118 mm x 60 mm x 30 mm (4.6" x 2.4" x 1.2")
Weight
220g (7.76 oz)
Sensor
Over 20 intelligent interchangeable field-replaceable electrochemical sensors
Battery
Rechargeable Li-ion battery
• Operating time > 30 hours (normal operation)
• Recharge time < 4 hours through charging cradle
Display
Graphical LCD display with white LED backlighting (activated when monitor
is in alarm or with a button press)
Display Readout
Real-time reading of concentrations in parts per million; battery status;
datalogging on/off status; wireless on/off and reception quality; STEL, TWA,
and peak values (as applicable)
Keypad
2 buttons for operation and programming
Sampling
Diffusion
Calibration
Automatic with AutoRAE 2 Test and Calibration Station or manual
Alarm Modes
Wireless remote alarm notification, audible (95dB @ 30cm), vibration, visible
alarm (flashing bright red LEDs), and on-screen indication of alarm conditions
• Additional diagnostic alarm and display message for low battery
Datalogging
• Continuous Datalogging with a three-month capacity (at one-minute
intervals)
• User-configurable datalogging interval (from 1 to 3,600 seconds)
Communication
and Data
Download
• Data download and instrument set-up on PC via charging and PC
communication cradle
• Data download via AutoRAE 2 Automated Test and Calibration Station
• Wireless data and status transmission via built-in RF modem (optional)
Wireless Network
RAE Systems Dedicated Wireless Network
Wireless
Frequency
ISM license-free bands
Wireless Range
(Typical)
300 feet (100 meters)
Operating
Temperature
-4° to 131° F (-20° to 55° C)
Humidity
0 to 95% relative humidity (non-condensing)
Dust and Water
Resistance
IP-65 rating for dust and water ingress protection (validated by an independent
test laboratory)
Hazardous
Location
Approvals
US and Canada
Class I, Div. 1; Groups A,B,C,D T4
Class I, Zone 0 A/Exia IIC T4
Europe
ATEX: II 1G, Ex ia IIC Ga T4
IECEx: Ex ia IIC Ga T4
China
Ex ia IIC T4
CE Compliance
(European
Conformity)
EMC directive: 2004/108/EC
R&TTE directive: 1999/5/EC
ATEX directive: 94/9/EC
Warranty
Two years on non-consumable components and CO, H
2
S, and O
2
sensors
One year on all other sensors, battery, and consumable parts
Specifications are subject to change.

Table of Contents

Related product manuals