Lists the types and ranges of gases the MultiRAE Plus can detect.
Describes the device's casing design and tool-less access to sensors.
Details the device's ruggedness, weatherproofing, power options, and safety certifications.
Identifies external ports and features of the device's durable casing.
Explains the faceplate layout, including alarm LEDs, light sensor, and function buttons.
Highlights the protective rubber casing, external filter, and belt clip.
Describes the pump's capabilities, sampling distance, filter protection, and flow rates.
Emphasizes the importance of using and replacing the external filter for device protection.
Step-by-step instructions on how to power on the MultiRAE Plus, including initial display messages.
Explains common warning messages during start-up, such as incorrect year or expired sensor warranty.
Details the procedure for performing a fresh air calibration after the warm-up period.
Describes how to verify sensor readings are within acceptable limits after calibration.
Explains the "Lamp" alarm indicating a failed PID lamp and troubleshooting steps.
Describes the "Pump" alarm indicating a blockage and how to resolve it.
Introduces the three operational display modes: Text, Display, and Advanced.
Compares the information displayed across Advanced, Display, and Text modes.
Details the main display showing real-time gas concentrations, alternating with sensor names.
Shows the highest readings recorded since the device was turned on and how to clear them.
Displays the lowest readings recorded since the device was turned on.
Shows the Short Term Exposure Limit, calculated over 15 minutes for VOCs and toxics.
Shows the Time Weighted Average, calculated over 8 hours for VOCs and toxics.
Indicates the current battery voltage and the shut-down threshold.
Shows the current date, time, accumulated run time, and internal temperature.
Explains the options for starting datalogging (Automatic, Manual, Scheduled).
Specifies the target gas used for LEL measurements, typically methane.
Specifies the target gas used for VOC measurements, typically isobutylene.
Describes the process for connecting the device to a PC for data transfer.
Explains that the device provides audible and visual alarms, and when they are disabled.
Indicates a VOC sensor exceeding the high alarm setpoint with specific audible/visual cues.
Indicates an Oxygen sensor reading below the low alarm setpoint.
Signals when the VOC sensor exceeds the Short Term Exposure Limit.
Signals when the VOC sensor exceeds the Time Weighted Average limit.
Indicates the LEL sensor has shut off due to overexposure and requires resetting.
Signals a VOC sensor drift to negative due to improper zeroing in a VOC environment.
Indicates the pump has stopped due to a line clog and requires clearing.
Alerts users to low battery voltage and imminent shutdown.
Notifies that the datalogging memory is full and needs clearing or configuration change.
Details how to enter programming mode using key combinations and the default password.
Lists the main configuration categories like calibration, alarm limits, datalogging, and setup.
Outlines Fresh Air, Multiple Sensor, and Single Sensor calibration procedures.
Step-by-step guide for calibrating multiple sensors using mixed calibration gas.
Explains the process for calibrating individual sensors, including VOC.
Allows adjustment of calibration gas values for different calibration gases.
Covers adjusting high, low, STEL, and TWA alarm thresholds with their associated signals.
Options to clear data, change period, data type, and memory full settings.
Includes changing site ID, user ID, alarm modes, and user modes.
Covers LEL/VOC gas selection, enabling/disabling sensors, and dilution ratios.
Instructions on how to properly turn off the MultiRAE Plus device.
Explains the charging process for Li-Ion and NiCad batteries and charge time.
Describes how the device maintains battery charge after reaching full capacity.
Details the installation of 4 AA alkaline batteries for extended operation.
Lists the types and ranges of gases the MultiRAE Plus can detect.
Describes the device's casing design and tool-less access to sensors.
Details the device's ruggedness, weatherproofing, power options, and safety certifications.
Identifies external ports and features of the device's durable casing.
Explains the faceplate layout, including alarm LEDs, light sensor, and function buttons.
Highlights the protective rubber casing, external filter, and belt clip.
Describes the pump's capabilities, sampling distance, filter protection, and flow rates.
Emphasizes the importance of using and replacing the external filter for device protection.
Step-by-step instructions on how to power on the MultiRAE Plus, including initial display messages.
Explains common warning messages during start-up, such as incorrect year or expired sensor warranty.
Details the procedure for performing a fresh air calibration after the warm-up period.
Describes how to verify sensor readings are within acceptable limits after calibration.
Explains the "Lamp" alarm indicating a failed PID lamp and troubleshooting steps.
Describes the "Pump" alarm indicating a blockage and how to resolve it.
Introduces the three operational display modes: Text, Display, and Advanced.
Compares the information displayed across Advanced, Display, and Text modes.
Details the main display showing real-time gas concentrations, alternating with sensor names.
Shows the highest readings recorded since the device was turned on and how to clear them.
Displays the lowest readings recorded since the device was turned on.
Shows the Short Term Exposure Limit, calculated over 15 minutes for VOCs and toxics.
Shows the Time Weighted Average, calculated over 8 hours for VOCs and toxics.
Indicates the current battery voltage and the shut-down threshold.
Shows the current date, time, accumulated run time, and internal temperature.
Explains the options for starting datalogging (Automatic, Manual, Scheduled).
Specifies the target gas used for LEL measurements, typically methane.
Specifies the target gas used for VOC measurements, typically isobutylene.
Describes the process for connecting the device to a PC for data transfer.
Explains that the device provides audible and visual alarms, and when they are disabled.
Indicates a VOC sensor exceeding the high alarm setpoint with specific audible/visual cues.
Indicates an Oxygen sensor reading below the low alarm setpoint.
Signals when the VOC sensor exceeds the Short Term Exposure Limit.
Signals when the VOC sensor exceeds the Time Weighted Average limit.
Indicates the LEL sensor has shut off due to overexposure and requires resetting.
Signals a VOC sensor drift to negative due to improper zeroing in a VOC environment.
Indicates the pump has stopped due to a line clog and requires clearing.
Alerts users to low battery voltage and imminent shutdown.
Notifies that the datalogging memory is full and needs clearing or configuration change.
Details how to enter programming mode using key combinations and the default password.
Lists the main configuration categories like calibration, alarm limits, datalogging, and setup.
Outlines Fresh Air, Multiple Sensor, and Single Sensor calibration procedures.
Step-by-step guide for calibrating multiple sensors using mixed calibration gas.
Explains the process for calibrating individual sensors, including VOC.
Allows adjustment of calibration gas values for different calibration gases.
Covers adjusting high, low, STEL, and TWA alarm thresholds with their associated signals.
Options to clear data, change period, data type, and memory full settings.
Includes changing site ID, user ID, alarm modes, and user modes.
Covers LEL/VOC gas selection, enabling/disabling sensors, and dilution ratios.
Instructions on how to properly turn off the MultiRAE Plus device.
Explains the charging process for Li-Ion and NiCad batteries and charge time.
Describes how the device maintains battery charge after reaching full capacity.
Details the installation of 4 AA alkaline batteries for extended operation.
| Brand | Rae |
|---|---|
| Model | MultiRAE Plus |
| Category | Measuring Instruments |
| Language | English |