Rae QRAE II User Manual

Rae QRAE II
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
QRAE II User’s Guide
Covers QRAE II Diffusion & Pump Models
with Firmware Version 3.60 or higher
P/N 020-4100-000 Rev. F
May 2013

Table of Contents

Other manuals for Rae QRAE II

Questions and Answers:

Rae QRAE II Specifications

General IconGeneral
Operating Temperature-20°C to 50°C (-4°F to 122°F)
Humidity0% to 95% relative humidity (non-condensing)
IP RatingIP-65
Power SupplyRechargeable Li-ion battery or alkaline battery adapter
Gas SensorsUp to four sensors (combustible, O2, CO, H2S, SO2, HCN)
DisplayLCD
Battery Life14 hours with rechargeable Li-ion battery
AlarmsVisual, audible, and vibrating alarms
Gas DetectionLEL, O2, CO, H2S
Data LoggingContinuous data logging
CommunicationIR

Summary

Safety and Operational Guidelines

Read Before Operating

Manual must be read by all responsible for using, maintaining, or servicing.

Cautionary Statements

Never operate monitor with cover removed. Battery operations only in non-hazardous areas.

General Information

Specifications

QRAE II Specifications

Details configuration, dimensions, weight, detectors, battery, operating time, display, keypad, sampling, range, alarms, calibration, protection, EM Immunity, data storage, communication, temp/humidity.

Turning The QRAE II On

Operating The QRAE II

Mode Overview

Explains Normal, Diagnostic, and Programming modes and their functions.

Diagnostic Mode

Programming Mode

Entering Programming Mode

Method to access Programming Mode from Normal or Diagnostic Mode.

Programming Mode Navigation

Calibration Procedures

Changing Alarm Limits

High Alarm Limit

Procedure to selectively set the high alarm limit for individual sensors.

Alarm Signal Summary

Over Range

Describes Over Range alarm conditions, buzzer, LED, and vibrator patterns.

High Alarm

Describes High Alarm conditions, buzzer, LED, and vibrator patterns.

Bump Testing & Calibrating The QRAE II

Connecting Calibration Gas (Pump Model Only)

Attaching calibration gas hose to the pump model for calibration.

Calibration Adapter Use

Connecting The Calibration Adapter (Diffusion Model Only)

Attaching calibration adapter to diffusion model for calibration.

Zero (Fresh Air) Calibration

Multiple Sensor Calibration

Calibration Process

Determining the second calibration point for multiple sensors simultaneously.

Single Sensor Calibration

Calibration Procedure

Determining the second calibration point for an individual sensor.

Connecting To A Computer

Maintenance

Battery Adapter Installation

Replacing Sensors

Troubleshooting

Cannot turn on power after charging

Solutions for power-on issues related to battery.

Technical Support

Hazardous Area Classification

Classification by Zones and Divisions

Information on hazardous area classifications (zones, divisions, temperature, groups).

Basic Operation

Programming Mode Operations

Alarm Limit Adjustments

Change Alarm Limits

Modifying high, low, STEL, and TWA alarm points for each sensor.

Bump Testing and Calibration

Zero Calibration Methods

Using Fresh Air

Setting the zero point using clean ambient air.

Sensor Calibration

Bump Testing & Calibrating QRAE II (Diffusion Version)

Zero Calibration Methods

Battery Replacement

Replacing the QRAE II Li-Ion Battery

Procedure for removing and replacing the Li-Ion battery.

Troubleshooting

Related product manuals