68 ESP-LX+ & LXi+ Installation, Programming, & Operation Guide
Watering starts when it
should not.
18.
MAN START / ADV. key has been pressed.
To cancel a program that has been manually started,
set the dial to OFF for three seconds. Then set the
dial back to AUTO.
19.
An unwanted start time may have been
entered.
Turn the dial to PROGRAM START TIMES and check
to see if any programs have an unwanted start time.
See page 21 for instructions on setting and
eliminating start times.
20.
Programs may be stacked. Programs A, B, and C will stack behind each other if
they are scheduled to start while another program
(other than D) is running. Check to make sure
Programs A, B, and C are not scheduled to start
when any program other than D is scheduled. Refer
to page 13.
Display flashes
FAULT #
21.
The controller has detected a short circuit on a
particular station. For example, if the display
flashes FAULT 4, it means there is a short
somewhere between the controller and station
#4.
Identify and repair the shorted circuit. See
Diagnostic Circuit Breaker on page 64, and
Troubleshooting Open and Shorted Valve Circuits
on page 43 for more information.
SYMPTOM POSSIBLE CAUSE SOLUTION