DIP SWITCH CONFIGURATION
C1 - FULL REV ERD
OFF Normal operation
ON
When closing, if the gate senses an obstruction (ERD),
the gate will stop and reverse all the way to the fully
open limit.
C2 - SLOW
OFF Normal operation
ON
Adds a slow start when the gate opens and a slow stop
when the gate closes. The slow stop is triggered by the
slow stop switch. (ONLY ON THE ALL SECURE RAIL
DRIVE OPERATOR)
Eliminates having to jumper the foot pedal plug (JP11) and the stop
input (JP3).
1 - Foot pedal plug bypass
ON Bypass Mode
OFF Active Mode
1 - Stop input plug bypass
ON Bypass Mode
OFF Active Mode
Manual ERD adjustments
Range 0 to 7
0 Most Sensitive
7 Least Sensitive
Switches from automatic ERD adjustment (Dip switch C7 & C8) and
Manual ERD adjustment (Rotary switch S8)
Left Automatic ERD (Dip C7 & C8)
Right Manual ERD (Rotary S8)
C3, C4, C5 & C6
OFF
No function. These 4 switches should not be turned to
the ‘on’ position.
C7 & C8 - ERD 1 & ERD 2
Switch 7 8 Sensitivity
OFF OFF Most Sensitive
OFF ON Medium Sensitivity
ON OFF Low Sensitivity
ON ON Least Sensitivity
DIP SWITCH S5 “C”
DIP SWITCH S7
ROTARY SWITCH S8
SLIDE SWITCH S9
WARNING:
Do not bypass the foot pedal plug on any unit that has a foot pedal.
Bypassing the foot pedal plug can cause damage to you operator,
voids all warranties, and may cause serious injury.