EasyManua.ls Logo

R&S ZNA26 - Page 1535

R&S ZNA26
1709 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNA
1535User Manual 1178.6462.02 ─ 20
Mixer delay measurements (R&S ZNA-K9)
[SENSe<Ch>:]FREQuency:MDELay:ACQuire.................................................................1535
[SENSe<Ch>:]FREQuency:MDELay:APERture...............................................................1535
[SENSe<Ch>:]FREQuency:MDELay:CDELay................................................................. 1536
[SENSe<Ch>:]FREQuency:MDELay:CDMode................................................................ 1536
[SENSe<Ch>:]FREQuency:MDELay:CONVersion........................................................... 1537
[SENSe<Ch>:]FREQuency:MDELay:CORRection[:STATe]............................................... 1537
[SENSe<Ch>:]FREQuency:MDELay:DIVide................................................................... 1537
[SENSe<Ch>:]FREQuency:MDELay:LTONe...................................................................1538
[SENSe<Ch>:]FREQuency:MDELay:RECeiver............................................................... 1538
[SENSe<Ch>:]FREQuency:MDELay:RPORt...................................................................1538
[SENSe<Ch>:]FREQuency:MDELay:UTONe.................................................................. 1538
[SENSe<Chn>:]FREQuency:MDELay:MSTate?...............................................................1539
MMEMory:LOAD:MDAData...........................................................................................1539
MMEMory:LOAD:MDCData...........................................................................................1539
MMEMory:STORe:MDCData.........................................................................................1540
[SENSe<Ch>:]FREQuency:MDELay:ACQuire
Starts a calibration sweep for the mixer delay measurement. As a prerequisite, the cali-
brated channel must have at least one mixer delay trace.
Suffix:
<Ch>
.
Channel number
Example: See MMEMory:LOAD:MDCData on page 1539.
Usage: Event
Manual operation: See "Mixer Dly Cal" on page 372
[SENSe<Ch>:]FREQuency:MDELay:APERture <Aperture value>
Defines the frequency difference between the upper and lower tone (aperture).
Suffix:
<Ch>
.
Channel number
Parameters:
<Aperture value> Aperture
Range: 0 Hz to 50 MHz
*RST: 0 Hz
Default unit: Hz