29
9. Technical Data
This cooker is designed for use on either:
• Natural gas (Cat I
2H
) at 20 mbar or
• LP gas (Cat I
3+
) Butane 29 mbar / Propane 37 mbar
NOTE: The natural gas and LP gas versions of these cookers are dierent models and CANNOT be converted from one gas
family to the other.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: GB, IE.
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural gas 20 mbar
230 / 400 V 50 HzButane 29 mbar
Propane 37 mbar
See the appliance badge for test pressures.
Dimensions
Overall height minimum 902 mm maximum 927 mm
Overall width 1100 mm
Overall depth 598 mm (to fascia); 650 mm (over handles)
Minimum space above the hotplate 650 mm
Refer to 'Positioning the Cooker'.
Ratings
Hotplate Bypass Screw
Natural Gas 20 mb L.P. Gas
Injector Injector
Wok burner 57 3.5 kW
Internal 80
3.5 kW (246 g/h)
Internal 54
External 129 External 77
Large burner 40 3.0 kW 134 3.0 kW (210 g/h) 87
Medium burner 32 1.7 kW 109 1.7 kW (119 g/h) 68
Small burner 28 1.0 kW 75 1.0 kW (70 g/h) 51
Grill 88 2.73kW 190 2.73kW (192g/h) 85
Ovens N/A 3.2kW 237 2.9kW (203g/h) 85
Warmer 0.16 kW
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.) : 0.26 kW.
DocNo.101-0010 - Technical data - 110 Gas - RM lidded