38
Technical Data
This cooker is category II
2H3+
It is supplied set for group H natural gas.
A conversion kit from NG to LP gas is included.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB/IE
Gas Electric
Natural Gas 20mbar 230V 50Hz
Butane 29mbar
Propane 37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height minimum 898mm maximum 925mm
Overall width 1100mm See ‘Positioning of Cooker’
Overall depth 648mm
Space for fixing See ‘Positioning of Cooker’
Minimum space above hotplate 650mm
Connections
Gas: Electric
Rp
1
/
2
at rear centre230V 50Hz
Ratings
Natural Gas L.P. Gas
Injector Injector
Hotplate
Wok burner 3.65kW internal 80 3.5kW (246g/h) internal 54
external 129 external 77
Large Burner 3.0kW 134 3.0kW (210g/h) 87
Medium Burners 1.7kW 109 1.7kW (119g/h) 68
Small Burner 1.0kW 75 1.0kW (70g/h) 51
Gas burner inputs based on Gross Calorific Value
Ovens Left hand Multi-function Oven Right hand Fan Oven
Fan element 2.5kW 2.5kW
Top element 1.2kW
Browning Element 1.15kW
Bottom element 1.0kW
Maximum total electrical load at 230V 5.1kW*
*approximate total including oven lights, oven fan etc.