EasyManua.ls Logo

Rapid RH25L - Declaration of TÜV Conformity

Rapid RH25L
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
2. Drain water clear of the machine.
3. cover the machine body when not in use.
BPlease clean this machine with household detergents or clean water, NEVER use
gasoline, thinners or any similar fuel.
CCheck bolts, cables and connections regularly.
. Trouble shooting
Common faults
Phenomenon
Possible reason
Not
failure
A.Noticeable White vaporous
cold air or water.
B. Plopping sound
A. The fan motor stops automatically for defrost.
B. There will be sound from the solenoid valve when
machine starts or ends to defrost.
C. During machine working or just stopping, a sound like
water flow, in 2~3 minutes of starting the machine. This
Sound comes from refrigerant flowing or water drainage
during dehumidification.
D. The plopping sound during the operation is caused by
expand on heating and contract on cooling of the heat
exchanger when temperature varies.
Recheck
Heat pump does not run
A. Power supply failure
B. Check manual power supply switch to make sure it is on.
C. Fuse burned.
D. If machine auto- protector has started (check failure
code display on controller).
E. Check whether machine automatic on or off was set.
!!Important:
Unscrew the water nozzle of inlet pipe to let the water
flow out.
When the water in machine freezes in winter
season,the titanium heat exchanger may be damaged.