5
Transport it in proper manner
1. Transport it in original package.
2. When moving the machine, do not lift the water nozzle since the titanium heat exchanger
inside the machine will be damaged. Please refer to the following wrong operation
picture:
Determining Optimum installation position
The location of the swimming pool heat pump is very important for efficient operation,
think about the following factors when choose the proper place:
Avoidance of air recirculation
Easy for wire and pipe connection and Water pipe line of long water lines (not
longer than 10m.) from heater to pool.
Easy for maintenance.
Drainage of condensation.
Pay attention to the following points:
1. The heat pump must be installed OUTSIDE in a well ventilated place to avoid air
recirculation or in a place with adequate room area both for installation and
maintenance. Please refer to the following illustration:
A minimum of 300mm of clearance from walls, shrubbery, equipment, etc. is required around the entire
pump circumference. This allows for ample air intake. No less than 800mm clearance on the air outlet is
required to prevent re-circulation of air. We recommend not placing the unit underneath eaves, decks, or
porches, as this causes recirculation of discharged air, or the efficiency of the heater will be reduced or
even stopped.