D
GB
GA 110 E
Installationsanleitung
Installation manual

Table of Contents

Questions and Answers

  • J
    Jason BellAug 2, 2025
    Why does my Rapido Boiler ignition automat report a fault shortly after the burner activates?
    • K
      Kevin SmithAug 2, 2025
      A fault report from the ignition automat shortly after the burner activates in your Rapido Boiler may be due to absent or insufficient ionization current (required minimum value 5 µA), a dirty or faulty ionization electrode, absent ignition, a faulty ignition transformer, or a faulty ignition automat. You should measure the ionization current. Check the cable connection in the ignition automat and to the electrode. Check whether the gas outlet of the burner lance under the ionization electrode is not clogged, and clean if necessary. Clean or replace the ionization electrode. Replace the ignition transformer. Replace the ignition automat.
  • D
    David WilliamsAug 9, 2025
    How to fix a noisy burner when my Rapido Boiler is activated?
    • M
      Mia RamseyAug 9, 2025
      A noisy burner when your Rapido Boiler activates can be caused by a wrong setting of the ignition electrode, faulty contact of ignition cables, a faulty insulator of the ignition electrode, or a worn-out cable of the ignition electrode. Check the distance between the ignition electrode and burner lance and earth rod. Check the connection to the ignition transformer and electrode. Replace the ignition electrode, or, if necessary, adjust the distance between the earth rod.
  • J
    jbrockAug 17, 2025
    What causes a fault in the ignition automat of my Rapido Boiler with irregular intervals?
    • J
      Jamie CantrellAug 17, 2025
      A fault in the ignition automat of your Rapido Boiler at irregular intervals can be caused by a wrong setting of the ignition electrode, a worn-out cable of the ignition electrode, a pressure regulator of the gas regulating valve that doesn't open temporarily, or a faulty ignition automat. Check the distance between the ignition electrode and burner lance and earth rod. Replace the ignition electrode, or adjust the distance to earth rod if necessary. Exchange the pressure controller. Check the gas flow pressure controller, whereas the gas pressure controller may also have been switched off. Replace the ignition automat.
  • W
    williamsthomasAug 25, 2025
    How to troubleshoot a Rapido Boiler with no power supply during commissioning fault report by ignition automat?
    • R
      Robert MarshallAug 25, 2025
      If your Rapido Boiler reports a commissioning fault due to no power supply, it could be due to a faulty fuse, wrongly connected phase and neutral, or air in the gas pipe. Check the fuses and connections; the 6.3 A fuse is located under the control panel. To replace the fuse, open the boiler front door, unscrew, and remove the black cover to the fuse cabinet. Check thermostat settings. Connect phase to clamp L and neutral conductor to clamp N (at plug). Vent air from the gas pipe.

Summary

Installation Manual

Symbols and Warning Indications

Explains symbols and descriptions for important indications.

Gas Leak Procedure

Step-by-step instructions for handling a gas smell emergency.

Waste Gas Leak Procedure

Instructions on what to do if waste gas is detected.

General Warning Precautions

Important warnings regarding storage, modifications, and air quality.

Product Description

Regulatory Compliance

Applicable Standards and Directives

Lists national, regional, and European standards for installation.

Warranty Information

Package Contents

Technical Dimensions

Technical Specifications

Installation Procedures

Boiler Room Requirements

Specifies requirements for the boiler room installation environment.

Heater Connections

Details on connecting heating water flow and return lines.

Gas Installation

Guidance for qualified installation engineers on gas supply piping.

Waste Gas Connection

Instructions for connecting the waste gas flue and chimney requirements.

Electrical Wiring

Boiler Sensor Connection

Details for connecting the boiler sensor (KF) for the rapidomatic system.

Control System Wiring

Connecting Rapidomatic Control Devices

Wiring instructions for various Rapidomatic control devices (T2S, T2.3 S).

Accessory Connections

Room Thermostat Connection

Instructions for connecting a room thermostat (RTU) for heating control.

Comfortmatic Remote Control

Wiring the Comfortmatic remote control to the RMF plug.

Gas Setting and Adjustment

Appliance Gas Check

Checking the appliance for correct gas type and Wobbe index.

Gas Setting by Air Vent Pressure

Procedure for adjusting gas pressure using the air vent method.

Gas Setting by Volumetric Method

Method for setting gas according to volumetric flow for natural gas.

Gas System Checks

Gas Flow Pressure Inspection

Checking the gas flow pressure for natural gas installations.

Functional Inspection

Checking the boiler's overall function after adjustments.

Conversion to Alternative Gas Type

Procedure for converting the boiler to a different gas type.

Initial Operation

Function Check Procedure

Steps to verify the correct functioning of the ignition and burner.

Safety and Switch Functions

Details on safety mechanisms and switch operations during function check.

Unlocking Safety Temperature Limiter

Procedure for resetting the safety temperature limiter (STL).

Unlocking Waste Gas Monitor

Instructions on how to reset or unlock the waste gas monitor.

Boiler Operation

Shutting Down the Installation

Instructions for short-term and long-term shutdown procedures.

Preventing Freezing Damage

Procedures to prevent freezing in the heating system during winter.

Maintenance and Servicing

Annual Maintenance Procedure

Detailed step-by-step guide for annual boiler maintenance and cleaning.

Control Panel Operation

Control Panel Components and Functions

Explanation of the control panel components and their operational functions.

Troubleshooting Common Faults

Fault Diagnosis and Remedies

Identifies common faults and provides solutions and remedies.

Electrical Circuit Diagram

Circuit Diagram Legend

Explanation of symbols and markings used in the electrical circuit diagram.

Declaration of Conformity