EasyManua.ls Logo

Ratio iX3M - Page 30

Ratio iX3M
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
S. STOP TIME: It sets the Safety Stops time in minutes.
You can set the time from 0 to 9 minutes (if 0 the Safety Stop is omitted)
Do you know what?:
The diff erent diving Institutions can recommend diff erent times for the Safety Stop. Ask your Instructor or your
diving Institution for the value to be set.
S. STOP DEPTH: It sets the Safety Stops depth.
You can set the Safety Stops depth between 3 and 9 metres.
The Safety Stop is carried out at the lower metre of the depth you have set .
(eg. if S.STOP DEPTH= 5 the stop is carried out from 5.9 metres)
The Safety Stop is recommended only for dives deeper than 9 metres.
The timer is re-set if the depth of 9 metres is passed again.
Do you know what?:
If in the dives with deco, a deco stop is set between 10 and 1 mt, the Safety Stop is automatically omitted.
DEEP STOP: It selects if use the Deep Stops and which algorithm is to be used to
calculate the DEEP STOPS:
OFF: Deep Stop unabled
STD: Standard Method (half of the max. depth for 2,5 minutes)
PYLE: Pyle Method (ask your instructor for the Pyle Method)
A
B
To reach this menu from the main
screen press in sequence:
DIVE SETTINGS
ALGORITHM:
GFL/GFH:
S.STOP TIME:
S.STOP DEPTH:
DEEP STOP:
WATER:
DIVE MODE:
B
A C D
EXIT
NEXT
ENTRY
+
_
BUL
93/93
3
5
OFF
SALT
SCUBA

Table of Contents