6 | Electrical connection
80.06.083_iCombiPro-iCombiClassic_IM_en-US 63 / 100
Unit size 20 half size GN, 20 full size GN
6.9 Connected loads of different voltage types
Maximum connection voltage
n
Maximum permissible tolerance for the input voltage: -15% to +10%
n
The unit can be used with frequencies of 50Hz and 60Hz without technical
modifications.
iCombi Pro, iCombi Classic Elektrogeräte
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6-2/3 (1 ph 208 V) 60 27.4 5.7 30 B
6 half size E (1 ph 208 V) 60 52 10.8 60 B
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6-2/3 (1 ph 240 V) 50/60 24 5.7 30 B
6 half size E (1 ph 240 V) 50/60 45 10.8 60 B
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6-2/3 (3 ph 208 V) 60 15.9 5.7 20 B
6 half size E (3 ph 208 V) 60 30 10.8 35 B
6 full size E (3 ph 208 V) 60 62.2 22.4 70 B
10 half size E (3 ph 208 V) 60 52.5 18.9 60 B
10 full size E (3 ph 208 V) 60 103.8 37.4 125 B
20 half size E (3 ph 208 V) 60 103.3 37.2 125 B