EasyManua.ls Logo

Rational iCombi Classic

Rational iCombi Classic
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 | Electrical connection
80.06.083_iCombiPro-iCombiClassic_IM_en-US 65 / 100
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6-2/3 (3 AC 240 V) 50/60 15.5 6.2 16 B
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6-2/3 E (3 AC 240 V) 60 15.5 5.7 20 B
6 half size E (3 AC 240 V) 60 26 10.8 35 B
6 full size E (3 AC 240 V) 60 53.9 22.4 70 B
10 half size E (3 AC 240 V) 60 45.5 18.9 60 B
10 full size E (3 AC 240 V) 60 90 37.4 125 B
20 half size E (3 AC 240 V) 60 89.5 37.2 125 B
20 full size E (3 AC 240 V) 60 163.3 67.9 200 B
iCombi Pro, iCombi Classic Gasgeräte
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6 half size G (1 ph 120 V) 60 5.0 0.6 15 F
10 half size G (1 ph 120 V) 60 7.5 0.9 15 B
20 half size G (1 ph 120 V) 60 10.8 1.3 15 F
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6 half size G (1 ph 208 V) 60 2.9 0.6 15 B
6 full size G (1 ph 208 V) 60 4.3 0.9 15 B
10 half size G (1 ph 208 V) 60 4.3 0.9 15 B
10 full size G (1 ph 208 V) 60 7.2 1.5 15 B
20 half size G (1 ph 208 V) 60 6.3 1.3 15 B
20 full size G (1 ph 208 V) 60 10.6 2.2 15 B
Hz Power con-
sumption
(A)
Power (kW) Fuse (A) RCD model
6 half size G (1 ph 240 V) 50/60 2.5 0.6 15 B
6 full size G (1 ph 240 V) 50/60 3.8 0.9 15 B
10 half size G (1 ph 240 V) 50/60 3.8 0.9 15 B
10 full size G (1 ph 240 V) 50/60 6.3 1.5 15 B

Table of Contents

Other manuals for Rational iCombi Classic

Related product manuals