58
Press the ENTER button twice to return to the submenu:
BATTERY: allows you to check the charge level of the battery
FW RELEASE: allows you to check the FW versions (to possibly
communicate to the service)
RADIO INFO: allows you to check the information regarding the
strength of the radio signal.
Slave Column:
RSSI 69 : indicates the level of the Radio signal (between 0 and
100) The optimum level is >50
CH 2 : radio channel on which the column communicates (chan-
nel 2)
ID 2 : number of the bridge column.
Master Column:
RSSI 64 : indicates the level of the Radio signal (between 0 and
100) The optimum level is >50
CH 2 : radio channel on which the column communicates (chan-
nel 2)
COL 2 : total number of the bridge columns.
B A T T E R Y 2 4 . 9 1 V
1 0 0 %
F W U 1 V 0 0 . 2 4 . 0 0
F W U 1 V 0 0 . 2 4 . 0 0
S L A V E R S S I 6 9
C H 2 I D 2
M A S T E R R S S I 6 4
C H 2 C O L 2
7
E) Using two or more power lifts (power lifts signify a set of 4, 6, or 8 columns)
The communication shall be performed on different channels, the rst congured power lift shall communicate on channel 2, and
the others on different channels (available from 0 to 9).
When a power lift is switched off and a new conguration is performed on another one, the transmission may take place on the
channel of the switched off power lift.
When it will be re-started, a new communication channel shall be suggested, which will be conrmed on all the columns in the set.
F) Simultaneous conguration of two or more power lifts
It is not possible.
If 2 master columns with open conguration are detected, the procedure is blocked.
All installations must be switched off.
Repeat the operation, close the conguration of the bridge before starting the set of a new machine.