Error Table
In the next tables a description of the different errors is given. Errors can be divided into two groups. Blocking errors will
disappear when error is gone, and non-volatile locking errors can only be reset by the reset button.
A blocking error is indicated with an ‘E’ prior to the error number. A locking error is indicated with an ‘A’ prior to the error
number. A detailed description of the different error codes is given below.
Non volatile locking errors
Locking errors are indicated with an ‘A’ alternating with the error code.
Fault Finding
‘A’ code Int nr. Error Description
1 1
20
21
24
Too many flame errors on
cooker
No flame detected after three ignition attempts for
cooker or three flame losses in one hour (dot on
display is on when flame loss is detected)
4 7
16
Overheat error detected on
cooker
Cooker temperature was above 270°C with the burner
on.
5 17 Sensor difference detected on
cooker.
Cooker sensors deviated more than 20°C for a period
of 10 minutes.
6 n/a n/a
7 n/a Spare error number n/a
8 10 E2prom version incorrect Parameter settings are incorrect
9 Internal board error Error on PCB
22
Blocking errors
Blocking errors are indicated with an ‘E’ alternating with the error code
‘E’ code Int nr. Error Description
2 52
60
Cooker_T1 error (open or
shorted)
Cooker_T1 open or shorted (dot on displays is on
when shorted).
3 51
59
Cooker_T2 error (open or
shorted)
Cooker_T2 open or shorted (dot on displays is on
when shorted).
4 44
45
46
Mains error Phase and neutral exchanged.
Bad earth connection.
Wrong mains frequency.
6 37 Cooker flame error Unexplained flame detected.
7 n/a Spare error number n/a
8 n/a Spare error number n/a
9 Internal board error Error with PCB