MAINTENANCE INTERVALS
Every 125 Service Hours
Battery - Check
WARNING
Always wear protective clothing and
eyeglasses when working with battery.
For further important battery safety
information, consult the Deutz [Engine]
Operation Manual.
Clean Terminals
1. Remove battery box lid.
2. Remove black negative (-) cable.
3. Clean terminal and clamp of any oxidation
buildup with stiff wire brush. (Stroke brush
away from your body to avoid hazardous
particles.)
4. Apply a light coat of petroleum jelly around
base of terminal.
5. Repeat same procedure for red positive (+)
cable.
6. Replace both cables.
Adjust Electrolyte Level
1. Remove battery box lid.
2. Remove each cap carefully by prying with a
screwdriver.
3. Electrolyte level should be 1/4" to 1/2" above
metal plates (just touching bottom of plastic fill
neck). Add distilled water as needed.
4. Replace both caps.