User Guide of RFL- RFL-C3000S
33
5 Alarms and Solutions
5.1 Alarms Display
When the laser establishes communication with the client software,all alarm states of the
laser can be displayed on Raycus software homepage,as shown in Figure 1615(Download the
Rsycus software and software manual, please log in to Raycus official website)
Figure 16The homepage of Raycussoftware
If any alarm occurs (except for Interlock alarm)when the laser is running, the homepage will
display the alarm that occurs, and the ALARM light (yellow) on the front panel of the laser will
light up, the laser will stop emitting and lock.
When the Interlock is abnormal, the output of Ready signal is low, and the Interlock state is
abnormal in the software homepage, but the laser is not locked, and the ALARM light (yellow)
is not lit. Theoutput of Ready signal is on high level when the Interlock is normal.
5.2 Alarm solutions
The instructions and solutionsof alarms are as follows: