Adjustingthecolorthreshold
Thecolorthreshold’sdefaultvalueis100%,youcan
adjustthissettingsothatlesscolors/shadesare
displayed.
FromtheFishnderapplicationmenu:
1.SelectSensitivitySettings.
2.SelectColorThreshold.
3.Adjustthecolorthresholdtotherequiredvalue.
4.SelectOktoconrmsettingandclosethe
numericadjustcontrol.
Powermode
Powermodecontrolsthepowerlevelofthe
transducer.Powermodecanbesettoautomaticor
adjustedmanuallybetween0%and100%.Power
modeisonlyavailableonCHIRP ,Traditionaland
Legacysonarmodules.
AutoThisisthedefaultsetting.Whenauto
isselectedthesonarmoduleautomatically
determinestheoptimumsettingbasedonthe
currentdepth,speed,and(bottom)signalstrength.
ManualYoucanadjustthepowerlevelbetween
in1%increments.Lowerpowerlevelsare
normallyusedindepthrangeslessthan2.4m(8
ft.)andhigherpowerlevelsaretypicallyselected
fordepthsgreaterthan3.7m(12ft.).
Adjustingthetransducerpowerlevel
FromtheFishnderapplicationmenu:
1.SelectSensitivitysettings.
2.SelectPowerMode.
Thepowermodesliderbarcontrolisdisplayed.
3.Adjustthesliderbartotherequiredsetting,or
4.SelectAutotosetautomaticpowermode.
15.19Fishnderalarms
ThefollowingFishnderalarmscanbesetwhena
depthdatasourceisavailable.
Fishalarmsoundswhenatargetmeetsthe
speciedsensitivityleveland,iswithinthedepth
limits(ifenabled).
FishnderDeepalarmsoundswhenthe
detecteddepthisgreaterthanthedeeplimit.
FishnderShallowalarmsoundswhenthe
detecteddepthislessthantheshallowlimit.
Settingupshalarms
FromtheAlarmsmenuhomescreen>Set-up>
Alarms:
1.SelectFish.
TheFishalarmsmenuisdisplayed.
2.SelectFishsothatOnishighlighted.
3.SelectFishSensitivity.
Theshsensitivitynumericadjustcontrolis
displayed.
4.Adjusttheshsensitivitytotherequirevalue.
Thegreatertheshalarmsensitivity,thegreater
thenumberoftargetimagedepthsdisplayed.
5.SelectFishDepthLimitssothatOnis
highlighted.
Theshallowanddeepshlimitsettingswillbe
activatedinthemenu.
6.SelectShallowFishLimit.
Theshallowshlimitnumericadjustcontrolis
displayed.
7.Adjustthevaluetotherequiresetting.
8.SelectOktoconrmthenewvalueandclosethe
numericadjustcontrol.
9.SelectDeepFishLimit.
Thedeepshlimitnumericadjustcontrolis
displayed.
10.Adjustthevaluetotherequiresetting.
11.SelectOktoconrmthenewvalueandclosethe
numericadjustcontrol.
Settingupshnderdeepalarm
FromtheAlarmsmenuhomescreen>Set-up>
Alarms:
1.SelectFishnderDeep.
2.SelectDeepsothatOnishighlighted.
SelectingDeepwillswitchbetweenOnandOff.
3.SelectDeepLimit.
Thedeeplimitnumericadjustcontrolisdisplayed.
4.Adjustthesettingtotherequiredvalue.
5.SelectOktoconrmthenewvalueandclosethe
numericadjustcontrol.
Note:TheDeepLimitcannotbesettolessthan
theShallowLimit.
Settingupshndershallowalarm
FromtheAlarmsmenuhomescreen>Set-up>
Alarms:
1.SelectFishnderShallow.