EasyManuals Logo

Raymarine c97 User Manual

Raymarine c97
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #260 background imageLoading...
Page #260 background image
18.18Measuringdistancesand
bearings
Youcanusethedatabarandcontextmenu
informationyoucanusethemeasurefunctionto
measuredistancesinthechartapplication.
Youcandeterminethedistanceandbearing:
fromyourvesseltothepositionofthecursor;
betweentwopointsonthechart.
Measuringfromvesselpositiontocursor
Fromthechartapplication:
1.Selectthelocationonscreenthatyouwant
tomeasurethedistanceorbearingfromyour
vessel.
Thechartcontextmenuwillbedisplayed.
2.SelectMeasure.
Thefollowingwillhappen:
Themeasuremenuwillbedisplayed.
Alinewillbedrawnfromthecursorpositionto
thecenterofthescreen.
Thecursorlocationwillbemovedatthecenter
ofthescreen.
Thebearinganddistancewillbedisplayed
nexttothenewcursorlocation.
3.FromthemeasuremenuselectFromsothat
Shipisselected.
Therulerlineisre-drawnfromthecursorposition
toyourvessel.
4.Youcannowadjusttherulerpositionbymoving
thecursortothedesiredlocation.
5.Ifyouwanttherulerdisplayedafteryouhave
closedthemeasuremenu,selectRuler:sothat
Onishighlighted.
SelectingrulerwillswitchtherulerOnandOff.
6.SelectBackorOktoclosethemeasuremenu
leavingthecurrentmeasurementon-screen.
Measuringfrompointtopoint
Fromthechartapplication:
1.Selectthelocationonscreenthatyouwant
tomeasurethedistanceorbearingfromyour
vessel.
Thechartcontextmenuwillbedisplayed.
2.SelectMeasure.
Thefollowingwillhappen:
Themeasuremenuwillbedisplayed.
Alinewillbedrawnfromthecursorpositionto
thecenterofthescreen.
Thecursorlocationwillbemovedatthecenter
ofthescreen.
Thebearinganddistancewillbedisplayed
nexttothenewcursorlocation.
3.SelectFromsothatCursorisselected.
SelectingmeasurefromwillswitchbetweenShip
andCursor.
4.Youcannowadjusttheendpointbymovingthe
cursortothedesiredlocation.
5.YoucanalsoSwapDirectionoftherulersothat
thebearingbecomesthebearingfromendpoint
tostartpoint.
6.Ifyouwanttherulerdisplayedafteryouhave
closedthemeasuremenu,selectRulersothat
Onishighlighted.
SelectingdisplayrulerwillswitchtherulerOn
andOff.
7.SelectBackorOktoexitthemeasuremenu
leavingthecurrentmeasurementon-screen.
Repositioningtheruler
Youcanrepositionarulerbyfollowingthesteps
below.
1.Selectthecurrentruler.
Therulercontextmenuisdisplayed.
2.SelectMeasure.
Youcannowrepositiontherulerasrequired.
260aSeries/cSeries/eSeries

Table of Contents

Other manuals for Raymarine c97

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine c97 and is the answer not in the manual?

Raymarine c97 Specifications

General IconGeneral
BrandRaymarine
Modelc97
CategoryMarine GPS System
LanguageEnglish

Related product manuals